XNH00-FCE-A160  ·  HS 8538.90
NH0 Switch-disconnector 3P 160A E (XNH00-FCE-A160)

Technical Specifications

Manufacturer part number (MPN)XNH00-FCE-A160
EAN / GTIN4015081779567
Sales unitpcs
Eaton catalogue number183029
Depth204 mm
Height117 mm
Width106 mm
Weight0.725 kg
CompliancesRoHS conform
CertificationsIEC/EN 60947-3
FeaturesStandard sealable; Electronic fuse monitoring and EMC (Electromagnetic compatibility) as of IEC 61000-4-4; Electronic fuse monitoring and EMC (Electromagnetic compatibility) as of IEC 61000-4-5; Halogen free
Fitted withConnectors; Error protection
Flammability characteristics (UL)Self-extinguishing (UL 94)
Special featuresPermanent operation (rated operating mode) Current paths of electrolytic copper, silver-plated with electronic monitoring of fuse-links
Suitable forGround mounting; Front mounting
Actuator typeCover grip
ColorGray
Number of polesThree-pole
TypeFuse control - electronic
Ambient operating temperature detailsAmbient temperature range: -25 °C - 70 °C Operating temperature range: -5 °C - 55 °C
Equipment heat dissipation, current-dependent9 W
Heat deflection temperature125 °C
Heat dissipation at 80% without fuses5.8 W
Heat dissipation per pole, current-dependent3 W
Rated operational current for specified heat dissipation (In)160 A
Total heat dissipation without fuses at Ith9 W
Creepage resistanceCTI 600
Direction of incoming supplyAs required
Electrical connection type of main circuitScrew connection
Electronic fuse monitoring1 NO; Self-supplied; 1.5 VA; NH with live handle straps; > 1 kOhm/V; 1 NC; 3 LEDs (F1, F2, F3) red; 1 LED green; Test button for relay + LEDs
Frequency rating40 Hz - 60 Hz
Frequency rating (electronic fuse monitoring)50 - 60 Hz
Frequency rating of contacts40 Hz - 60 Hz
Lifespan, electrical300 operations
Operating altitude without derating - max2000 mm
Overvoltage categoryII (500 V); III (230/400 V); III
Permitted power loss per fuse link - max12 W
Pollution degree3
Rated conditional short-circuit rating100 kA (690 V); 120 kA (500 V)
Rated impulse withstand voltage (Uimp)8 kV
Rated insulation voltage (Ui)800 VAC
Rated operating voltage (Ue) at AC - max500 V
Rated operation current (Ie)160 A
Rated operational current160 A; 160 A (AC-22B); 160 A (AC-21B); 160 A (AC-23B)
Rated short-time withstand current (Icw)7 kA
Rated uninterrupted current (Iu)160 A
Switching current of electronic fuse monitoring - max1 A
Voltage inputs400 V AC - 500 V AC (+/-10%)
Voltage rating at AC400 V (AC-23B) 500 V (AC-22B) 690 V (AC-21B)
Voltage rating at AC - max250 VAC
Voltage rating at DC250 V DC at DC-22B 440 V DC at DC-21B
Voltage rating at DC - max24 VDC
Voltage testYes, sliding inspection windows
Conditioned rated short-circuit current Iq120 kA
Rated conditional short-circuit current (Iq)120 kA
Activation typeDependent manual activation
Actuator positionFront side
Cable entry typeOther
Degree of protection (front side)Other
Lifespan, mechanical1400 operations
Locking facilityYes, optional
MaterialPolyamide
Mounting methodMounting plate; DIN rail
Mounting positionVertical or horizontal
SizeNH000 / NH00 fuse
Suitable for fusesNH00
Terminal capacity (copper band)9 mm x 0.8 mm (6x) at box terminal
Terminal capacity (copper busbar)Bolt diameter at flange connection: M8; 20 mm x 10 mm; Max. 25 mm cable lug width at flange connection
Terminal capacity (copper strip)9 mm x 0.8 mm (9x) at box terminal
Terminal capacity (stranded cable)1.5 mm² - 50 mm² at box terminal; 10 mm² - 70 mm² at clamp-type terminal; 1.5 mm² - 95 mm² at box terminal
Connection typeFlat connection
Degree of protectionIP3X; IP2XC (contact protection, XNH installed); IP20 (operating status, XNH installed); IP10 (handle cover open, XNH installed)
Rated permanent current Iu160 A
Motor drive integratedNo
Type of electrical connection of main circuitScrew connection
Version as emergency stop installationNo
Type of control elementCover grip
Version as main switchNo
Version as safety switchNo
Rated short-time withstand current lcw7 kA
Suitable for floor mountingYes
Suitable for front mountingYes
Suitable for busbar mountingNo
Max. rated operation voltage Ue AC500 V
With error protectionYes
Motor drive optionalNo
Position control elementFront side
Equipped with connectorsYes
Country of originGermany