cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Selector switch, hastighetskontroll (T0-4-8441/E)

Eaton · Switchgear & Protection · Disconnect Switches · Ireland · eaton.com
Part Number
T0-4-8441/E  ·  HS 8536.50
Selector switch, hastighetskontroll (T0-4-8441/E)

Eaton T0-4-8441/E Dahlanderkobling, recessed, 1-0-2 - 3 / 4 / 4 / 4 kW AC-1 20A.

Technical Specifications

Manufacturer part number (MPN)T0-4-8441/E
EAN / GTIN4015080435952
Sales unitpcs
Eaton catalogue number043595
Depth105 mm
Height48 mm
Width48 mm
Weight0.156 kg
CertificationsCE; CSA File No.: 012528; IEC/EN 60947-3; IEC/EN 60947; UL; VDE 0660; IEC/EN 60204; CSA Class No.: 3211-05; CSA-C22.2 No. 60947-4-1-14; UL File No.: E36332; UL 60947-4-1; UL Category Control No.: NLRV; CSA-C22.2 No. 94; CSA
Catalog NotesRated Short-time Withstand Current (Icw) for a time of 1 second
Actuator functionWith 0 (Off) position; Maintained
Actuator typeShort thumb-grip
Ambient operating temperature - max50 °C
Ambient operating temperature - min-25 °C
Ambient operating temperature (enclosed) - max40 °C
Ambient operating temperature (enclosed) - min-25 °C
Climatic proofingDamp heat, constant, to IEC 60068-2-78; Damp heat, cyclic, to IEC 60068-2-30
Control circuit reliability1 failure per 100,000 switching operations statistically determined, at 24 V DC, 10 mA)
Number of auxiliary contacts (change-over contacts)0
Number of auxiliary contacts (normally closed contacts)0
Number of auxiliary contacts (normally open contacts)0
Number of contacts8
Heat dissipation per pole, current-dependent Pvid0.6 W
Rated operational current for specified heat dissipation (In)20 A
Rated breaking capacity at 220/230 V (cos phi to IEC 60947-3)100 A
Rated breaking capacity at 400/415 V (cos phi to IEC 60947-3)110 A
Rated breaking capacity at 500 V (cos phi to IEC 60947-3)80 A
Rated breaking capacity at 660/690 V (cos phi to IEC 60947-3)60 A
Rated operational current (Ie)20 A at AC-3, 400 V star-delta; 8.5 A at AC-3, 690 V star-delta; 20 A at AC-3, 230 V star-delta; 15.6 A at AC-3, 500 V star-delta
Rated operational current (Ie) at AC-21, 440 V20 A
Rated operational current (Ie) at AC-23A, 230 V13.3 A
Rated operational current (Ie) at AC-23A, 400 V, 415 V13.3 A
Rated operational current (Ie) at AC-23A, 500 V13.3 A
Rated operational current (Ie) at AC-23A, 690 V7.6 A
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V11.5 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V11.5 A
Rated operational current (Ie) at AC-3, 500 V9 A
Rated operational current (Ie) at AC-3, 660 V, 690 V4.9 A
Rated operational current (Ie) at DC-13, control switches L/R = 50 ms10 A
Rated operational current (Ie) at DC-21, 240 V1 A
Rated operational current (Ie) at DC-23A, 120 V5 A
Rated operational current (Ie) at DC-23A, 24 V10 A
Rated operational current (Ie) at DC-23A, 240 V5 A
Rated operational current (Ie) at DC-23A, 48 V10 A
Rated operational current (Ie) at DC-23A, 60 V10 A
Rated operational power at AC-23A, 220/230 V, 50 Hz3 kW
Rated operational power at AC-23A, 400 V, 50 Hz5.5 kW
Rated operational power at AC-23A, 500 V, 50 Hz7.5 kW
Rated operational power at AC-23A, 690 V, 50 Hz5.5 kW
Rated operational power at AC-3, 380/400 V, 50 Hz4 kW
Rated operational power at AC-3, 415 V, 50 Hz5.5 kW
Rated operational power at AC-3, 690 V, 50 Hz4 kW
Rated operational power star-delta at 220/230 V, 50 Hz5.5 kW
Rated operational power star-delta at 380/400 V, 50 Hz7.5 kW
Rated operational power star-delta at 500 V, 50 Hz7.5 kW
Rated operational power star-delta at 690 V, 50 Hz5.5 kW
Rated operational voltage (Ue) at AC - max690 V
Rated uninterrupted current (Iu)20 A
Uninterrupted currentRated uninterrupted current Iu is specified for max. cross-section.
Enclosure materialPlastic
Fitted withBlack thumb grip and front plate; 0 (off) position
Inscription1-0-2
Number of poles3
Switch function typeOne tapped winding, 2 speeds
Degree of protectionNEMA 12; IP65; NEMA 1
Degree of protection (front side)IP65; NEMA 12
Lifespan, mechanical400,000 Operations
ModelDahlander switch
Mounting methodFlush mounting
Mounting positionAs required
Number of contact units4
Operating frequency1200 Operations/h
Overvoltage categoryIII
Pollution degree3
Product CategoryControl switches
Rated impulse withstand voltage (Uimp)6000 V AC
Safe isolation440 V AC, Between the contacts, According to EN 61140
Safety parameter (EN ISO 13849-1)B10d values as per EN ISO 13849-1, table C.1
Shock resistance15 g, Mechanical, According to IEC/EN 60068-2-27, Half-sinusoidal shock 20 ms
Suitable forBranch circuits, suitable as motor disconnect, (UL/CSA); Front mounting
Switching angle60 °
TypeMulti-speed switch
Assigned motor power at 115/120 V, 60 Hz, 1-phase0.5 HP
Assigned motor power at 200/208 V, 60 Hz, 1-phase1 HP
Assigned motor power at 200/208 V, 60 Hz, 3-phase3 HP
Assigned motor power at 230/240 V, 60 Hz, 1-phase1.5 HP
Assigned motor power at 230/240 V, 60 Hz, 3-phase3 HP
Assigned motor power at 460/480 V, 60 Hz, 3-phase7.5 HP
Assigned motor power at 575/600 V, 60 Hz, 3-phase7.5 HP
Rated conditional short-circuit current (Iq)6 kA
Rated short-time withstand current (Icw)320 A, Contacts, 1 second
Short-circuit current rating (basic rating)5 kA, SCCR (UL/CSA); 50A, max. Fuse, SCCR (UL/CSA)
Short-circuit current rating (high fault)20 A, Class J, max. Fuse, SCCR (UL/CSA); 10 kA, SCCR (UL/CSA)
Short-circuit protection rating20 A gG/gL, Fuse, Contacts
Load rating1.6 x Iₑ (with intermittent operation class 12, 40 % duty factor); 2 x Iₑ (with intermittent operation class 12, 25 % duty factor); 1.3 x Iₑ (with intermittent operation class 12, 60 % duty factor)
Number of contacts in series at DC-21A, 240 V1
Number of contacts in series at DC-23A, 120 V3
Number of contacts in series at DC-23A, 24 V1
Number of contacts in series at DC-23A, 240 V5
Number of contacts in series at DC-23A, 48 V2
Number of contacts in series at DC-23A, 60 V3
Rated making capacity up to 690 V (cos phi to IEC/EN 60947-3)130 A
Switching capacity (auxiliary contacts, general use)10A, IU, (UL/CSA)
Switching capacity (auxiliary contacts, pilot duty)A600 (UL/CSA); P300 (UL/CSA)
Switching capacity (main contacts, general use)16 A, Rated uninterrupted current max. (UL/CSA)
Voltage per contact pair in series60 V
Screw sizeM3.5, Terminal screw
Terminal capacity (flexible with ferrule)1 x (0.75 - 2.5) mm², ferrules to DIN 46228; 2 x (0.75 - 2.5) mm², ferrules to DIN 46228
Terminal capacity (solid/flexible with ferrule AWG)18 - 14
Terminal capacity (solid/stranded)1 x (1 - 2.5) mm²; 2 x (1 - 2.5) mm²
Tightening torque8.8 lb-in, Screw terminals; 1 Nm, Screw terminals
Rated operation power at AC-3, 400 V4 kW
Rated permanent current Iu20 A
Rated operation current Ie at AC-3, 400 V11.5 A
With zero (off) positionYes
Housing materialPlastic
With retraction in 0-positionNo
Degree of protection (IP), front sideIP65
Type of electrical connection of main circuitScrew connection
Type of control elementWing knob
Suitable for floor mountingNo
Suitable for front mountingYes
Suitable for distribution board installationNo
Suitable for intermediate mountingNo
Complete device in housingNo
Country of originUnited Kingdom

Properties

MOQ1

Cross-References