Step Switch (T0-2-96/I1)

Eaton · Switchgear & Protection · Disconnect Switches · Ireland · eaton.com
Part Number
T0-2-96/I1  ·  HS 8536.50
Step Switch (T0-2-96/I1)

Eaton T0-2-96/I1 Reguleringsbrytere for different elements, 2-pole. Enclosed - 20 A.

Technical Specifications

Manufacturer part number (MPN)T0-2-96/I1
EAN / GTIN4015082226282
Sales unitpcs
Eaton catalogue number222628
Depth137 mm
Height102 mm
Width80 mm
Weight0.264 kg
CertificationsVDE 0660; IEC/EN 60947-3; IEC/EN 60947; IEC/EN 60204
Catalog NotesRated Short-time Withstand Current (Icw) for a time of 1 second
Actuator functionMaintained; With 0 (Off) position
Actuator typeShort thumb-grip
Ambient operating temperature - max40 °C
Ambient operating temperature - min-25 °C
Ambient operating temperature (enclosed) - max40 °C
Ambient operating temperature (enclosed) - min-25 °C
Climatic proofingDamp heat, cyclic, to IEC 60068-2-30; Damp heat, constant, to IEC 60068-2-78
Control circuit reliability1 failure per 100,000 switching operations statistically determined, at 24 V DC, 10 mA)
Number of auxiliary contacts (change-over contacts)0
Number of auxiliary contacts (normally closed contacts)0
Number of auxiliary contacts (normally open contacts)0
Number of contacts3
Heat dissipation per pole, current-dependent Pvid0.6 W
Rated operational current for specified heat dissipation (In)20 A
Rated breaking capacity at 220/230 V (cos phi to IEC 60947-3)100 A
Rated breaking capacity at 400/415 V (cos phi to IEC 60947-3)110 A
Rated breaking capacity at 500 V (cos phi to IEC 60947-3)80 A
Rated breaking capacity at 660/690 V (cos phi to IEC 60947-3)60 A
Rated operational current (Ie)20 A at AC-3, 230 V star-delta; 20 A at AC-3, 400 V star-delta; 8.5 A at AC-3, 690 V star-delta; 15.6 A at AC-3, 500 V star-delta
Rated operational current (Ie) at AC-21, 440 V20 A
Rated operational current (Ie) at AC-23A, 230 V13.3 A
Rated operational current (Ie) at AC-23A, 400 V, 415 V13.3 A
Rated operational current (Ie) at AC-23A, 500 V13.3 A
Rated operational current (Ie) at AC-23A, 690 V7.6 A
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V11.5 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V11.5 A
Rated operational current (Ie) at AC-3, 500 V9 A
Rated operational current (Ie) at AC-3, 660 V, 690 V4.9 A
Rated operational current (Ie) at DC-13, control switches L/R = 50 ms10 A
Rated operational current (Ie) at DC-21, 240 V1 A
Rated operational current (Ie) at DC-23A, 120 V5 A
Rated operational current (Ie) at DC-23A, 24 V10 A
Rated operational current (Ie) at DC-23A, 240 V5 A
Rated operational current (Ie) at DC-23A, 48 V10 A
Rated operational current (Ie) at DC-23A, 60 V10 A
Rated operational power at AC-23A, 220/230 V, 50 Hz3 kW
Rated operational power at AC-23A, 400 V, 50 Hz5.5 kW
Rated operational power at AC-23A, 500 V, 50 Hz7.5 kW
Rated operational power at AC-23A, 690 V, 50 Hz5.5 kW
Rated operational power at AC-3, 380/400 V, 50 Hz4 kW
Rated operational power at AC-3, 415 V, 50 Hz5.5 kW
Rated operational power at AC-3, 690 V, 50 Hz4 kW
Rated operational power star-delta at 220/230 V, 50 Hz5.5 kW
Rated operational power star-delta at 380/400 V, 50 Hz7.5 kW
Rated operational power star-delta at 500 V, 50 Hz7.5 kW
Rated operational power star-delta at 690 V, 50 Hz5.5 kW
Rated operational voltage (Ue) at AC - max690 V
Rated uninterrupted current (Iu)20 A
Uninterrupted currentRated uninterrupted current Iu is specified for max. cross-section.
Enclosure materialPlastic
FeaturesComplete device in housing
Fitted with0 (off) position; Black thumb grip and front plate
Inscription0-3
Number of poles1
Degree of protectionIP65
Degree of protection (front side)IP65; NEMA 12
Lifespan, mechanical400,000 Operations
ModelReverser
Mounting methodSurface mounting
Mounting positionAs required
Number of contact units2
Operating frequency1200 Operations/h
Overvoltage categoryIII
Pollution degree3
Product CategoryControl switches
Rated impulse withstand voltage (Uimp)6000 V AC
Safe isolation440 V AC, Between the contacts, According to EN 61140
Safety parameter (EN ISO 13849-1)B10d values as per EN ISO 13849-1, table C.1
Shock resistance15 g, Mechanical, According to IEC/EN 60068-2-27, Half-sinusoidal shock 20 ms
Suitable forGround mounting; Front mounting
Switching angle60 °
TypeStep switch for heating
Rated conditional short-circuit current (Iq)6 kA
Rated short-time withstand current (Icw)320 A, Contacts, 1 second
Short-circuit protection rating20 A gG/gL, Fuse, Contacts
Load rating2 x Iₑ (with intermittent operation class 12, 25 % duty factor); 1.3 x Iₑ (with intermittent operation class 12, 60 % duty factor); 1.6 x Iₑ (with intermittent operation class 12, 40 % duty factor)
Number of contacts in series at DC-21A, 240 V1
Number of contacts in series at DC-23A, 120 V3
Number of contacts in series at DC-23A, 24 V1
Number of contacts in series at DC-23A, 240 V5
Number of contacts in series at DC-23A, 48 V2
Number of contacts in series at DC-23A, 60 V3
Rated making capacity up to 690 V (cos phi to IEC/EN 60947-3)130 A
Voltage per contact pair in series60 V
Screw sizeM3.5, Terminal screw
Terminal capacity (flexible with ferrule)1 x (0.75 - 2.5) mm², ferrules to DIN 46228; 2 x (0.75 - 2.5) mm², ferrules to DIN 46228
Terminal capacity (solid/stranded)1 x (1 - 2.5) mm²; 2 x (1 - 2.5) mm²
Tightening torque1 Nm, Screw terminals
Rated operation power at AC-3, 400 V4 kW
Rated permanent current Iu20 A
Rated operation current Ie at AC-3, 400 V11.5 A
With zero (off) positionYes
Housing materialPlastic
With retraction in 0-positionNo
Degree of protection (IP), front sideIP65
Type of electrical connection of main circuitScrew connection
Type of control elementWing knob
Suitable for floor mountingYes
Suitable for front mountingYes
Suitable for distribution board installationNo
Suitable for intermediate mountingNo
Complete device in housingYes
Country of originUnited Kingdom

Properties