| Manufacturer part number (MPN) | P5-160/EA/SVB |
| EAN / GTIN | 4015082809225 |
| Sales unit | pcs |
| Eaton catalogue number | 280922 |
| Depth | 115 mm |
| Height | 150 mm |
| Width | 130 mm |
| Weight | 1.142 kg |
| Certifications | CE; UL File No.: E36332; IEC/EN 60947-3; VDE 0660; CSA File No.: 223805; UL 508; CSA Class No.: 3211-05; IEC/EN 60947; CSA; CSA-C22.2 No. 94; UL Category Control No.: NLRV, NLRV7; CSA-C22.2 No. 14-05; IEC/EN 60204; UL |
| Catalog Notes | Rated Short-time Withstand Current (Icw) for a time of 1 second |
| Actuator color | Red |
| Actuator type | Door coupling rotary drive |
| Ambient operating temperature - max | 50 °C |
| Ambient operating temperature - min | -25 °C |
| Ambient operating temperature (enclosed) - max | 40 °C |
| Ambient operating temperature (enclosed) - min | -25 °C |
| Climatic proofing | Damp heat, cyclic, to IEC 60068-2-30; Damp heat, constant, to IEC 60068-2-78 |
| Control circuit reliability | 1 failure per 100,000 switching operations statistically determined, at 24 V DC, 10 mA) |
| Number of auxiliary contacts (change-over contacts) | 0 |
| Number of auxiliary contacts (normally closed contacts) | 0 |
| Number of auxiliary contacts (normally open contacts) | 0 |
| Equipment heat dissipation, current-dependent Pvid | 5 W |
| Heat dissipation per pole, current-dependent Pvid | 5 W |
| Rated operational current for specified heat dissipation (In) | 160 A |
| Rated breaking capacity at 220/230 V (cos phi to IEC 60947-3) | 900 A |
| Rated breaking capacity at 400/415 V (cos phi to IEC 60947-3) | 850 A |
| Rated breaking capacity at 500 V (cos phi to IEC 60947-3) | 850 A |
| Rated breaking capacity at 660/690 V (cos phi to IEC 60947-3) | 340 A |
| Rated operational current (Ie) at AC-21, 440 V | 160 A |
| Rated operational current (Ie) at AC-23A, 230 V | 103 A |
| Rated operational current (Ie) at AC-23A, 400 V, 415 V | 105 A |
| Rated operational current (Ie) at AC-23A, 500 V | 106 A |
| Rated operational current (Ie) at AC-23A, 690 V | 42 A |
| Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V | 103 A |
| Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V | 85 A |
| Rated operational current (Ie) at AC-3, 500 V | 80 A |
| Rated operational current (Ie) at AC-3, 660 V, 690 V | 42 A |
| Rated operational current (Ie) at DC-23A, 120 V | 50 A |
| Rated operational current (Ie) at DC-23A, 24 V | 160 A |
| Rated operational current (Ie) at DC-23A, 48 V | 160 A |
| Rated operational current (Ie) at DC-23A, 60 V | 160 A |
| Rated operational power at AC-23A, 220/230 V, 50 Hz | 30 kW |
| Rated operational power at AC-23A, 400 V, 50 Hz | 55 kW |
| Rated operational power at AC-23A, 500 V, 50 Hz | 75 kW |
| Rated operational power at AC-23A, 690 V, 50 Hz | 37 kW |
| Rated operational power at AC-3, 380/400 V, 50 Hz | 45 kW |
| Rated operational power at AC-3, 415 V, 50 Hz | 45 kW |
| Rated operational power at AC-3, 500 V, 50 Hz | 55 kW |
| Rated operational power at AC-3, 690 V, 50 Hz | 37 kW |
| Rated operational voltage (Ue) at AC - max | 690 V |
| Rated uninterrupted current (Iu) | 160 A |
| Uninterrupted current | Rated uninterrupted current Iu is specified for max. cross-section. |
| Features | Version as emergency stop installation; Version as maintenance-/service switch; Version as main switch |
| Fitted with | Red rotary handle and yellow locking ring |
| Functions | Emergency switching off function; Interlockable |
| Locking facility | Lockable in the 0 (Off) position |
| Number of poles | 3 |
| Accessories | Auxiliary contact or neutral conductor fitted by user. |
| Degree of protection | NEMA 12 |
| Degree of protection (front side) | IP65 |
| Lifespan, mechanical | 100,000 Operations |
| Mounting method | Flush mounting |
| Mounting position | As required |
| Operating frequency | 50 Operations/h |
| Overvoltage category | III |
| Pollution degree | 3 |
| Product Category | Main switch |
| Rated impulse withstand voltage (Uimp) | 8000 V AC |
| Safe isolation | 440 V AC, Between the contacts, According to EN 61140 |
| Safety parameter (EN ISO 13849-1) | B10d values as per EN ISO 13849-1, table C.1 |
| Suitable for | Front mounting 4-hole; Branch circuits, suitable as motor disconnect, (UL/CSA) |
| Assigned motor power at 115/120 V, 60 Hz, 1-phase | 10 HP |
| Assigned motor power at 115/120 V, 60 Hz, 3-phase | 20 HP |
| Assigned motor power at 230/240 V, 60 Hz, 1-phase | 25 HP |
| Assigned motor power at 230/240 V, 60 Hz, 3-phase | 40 HP |
| Assigned motor power at 277 V, 60 Hz, 1-phase | 25 HP |
| Assigned motor power at 460/480 V, 60 Hz, 3-phase | 60 HP |
| Assigned motor power at 575/600 V, 60 Hz, 3-phase | 60 HP |
| Rated conditional short-circuit current (Iq) | 30 kA |
| Rated short-time withstand current (Icw) | 3 kA, Contacts, 1 second; 3 kA |
| Short-circuit current rating (basic rating) | 10 kA, SCCR (UL/CSA); 400A Class RK1, max. Fuse, SCCR (UL/CSA) |
| Short-circuit current rating (high fault) | 65 kA, SCCR (UL/CSA); 300 A, Class J, max. Fuse, SCCR (UL/CSA) |
| Short-circuit protection rating | 160 A gG/gL, Fuse, Contacts |
| Load rating | 1.6 x Iₑ (with intermittent operation class 12, 40 % duty factor); 2 x Iₑ (with intermittent operation class 12, 25 % duty factor); 1.3 x Iₑ (with intermittent operation class 12, 60 % duty factor) |
| Number of contacts in series at DC-23A, 120 V | 3 |
| Number of contacts in series at DC-23A, 24 V | 3 |
| Number of contacts in series at DC-23A, 48 V | 3 |
| Number of contacts in series at DC-23A, 60 V | 3 |
| Rated making capacity up to 690 V (cos phi to IEC/EN 60947-3) | 1050 A |
| Switching capacity (auxiliary contacts, general use) | 10A, IU, (UL/CSA) |
| Switching capacity (auxiliary contacts, pilot duty) | A600 (UL/CSA) |
| Switching capacity (main contacts, general use) | 200 A, Rated uninterrupted current max. (UL/CSA) |
| Voltage per contact pair in series | 42 V |
| Screw size | 5 mm AF, Hexagon socket-head spanner, Terminal screw |
| Tightening torque | 14 Nm, Screw terminals; 125 lb-in, Screw terminals |
| Country of origin | Germany |