cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Safety Switch (P3-63/I4/SVB/N)

Eaton · Switchgear & Protection · Safety Switches · Ireland · eaton.com
Part Number
P3-63/I4/SVB/N  ·  HS 8536.50
Safety Switch (P3-63/I4/SVB/N)

Technical Specifications

Manufacturer part number (MPN)P3-63/I4/SVB/N
EAN / GTIN4015082073497
Sales unitpcs
Eaton catalogue number207349
Depth139 mm
Height180 mm
Width160 mm
Weight1.228 kg
CompliancesCE Marked
CertificationsEN 60947-3; IEC 60947; CSA Std. C22.2 No. 14-05; UL 508; VDE; IEC/EN 60204; CE; CSA Class No.: 3211-05; CSA-C22.2 No. 60947-4-1-14; IEC/EN 60947-3; UL File No.: E36332; CSA-C22.2 No. 94; VDE 0660; UL; CSA File No.: 012528; IEC/EN 60947; UL Category Control No.: NLRV; CSA; UL 60947-4-1
Catalog NotesRated Short-time Withstand Current (Icw) for a time of 1 second
Actuator colorRed
Actuator typeDoor coupling rotary drive
Ambient operating temperature - max40 °C
Ambient operating temperature - min-25 °C
Ambient operating temperature (enclosed) - max40 °C
Ambient operating temperature (enclosed) - min-25 °C
Climatic proofingDamp heat, constant, to IEC 60068-2-78; Damp heat, cyclic, to IEC 60068-2-30
Control circuit reliability1 failure per 100,000 switching operations statistically determined, at 24 V DC, 10 mA)
Number of auxiliary contacts (change-over contacts)0
Number of auxiliary contacts (normally closed contacts)0
Number of auxiliary contacts (normally open contacts)0
Equipment heat dissipation, current-dependent Pvid4.5 W
Heat dissipation per pole, current-dependent Pvid4.5 W
Rated operational current for specified heat dissipation (In)63 A
Rated breaking capacity at 220/230 V (cos phi to IEC 60947-3)640 A
Rated breaking capacity at 400/415 V (cos phi to IEC 60947-3)600 A
Rated breaking capacity at 500 V (cos phi to IEC 60947-3)590 A
Rated breaking capacity at 660/690 V (cos phi to IEC 60947-3)340 A
Rated operational current (Ie) at AC-21, 440 V63 A
Rated operational current (Ie) at AC-23A, 230 V63 A
Rated operational current (Ie) at AC-23A, 400 V, 415 V63 A
Rated operational current (Ie) at AC-23A, 500 V63 A
Rated operational current (Ie) at AC-23A, 690 V63 A
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V51 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V55 A
Rated operational current (Ie) at AC-3, 500 V44 A
Rated operational current (Ie) at AC-3, 660 V, 690 V22.1 A
Rated operational current (Ie) at DC-23A, 120 V25 A
Rated operational current (Ie) at DC-23A, 24 V50 A
Rated operational current (Ie) at DC-23A, 48 V50 A
Rated operational current (Ie) at DC-23A, 60 V50 A
Rated operational power at AC-23A, 220/230 V, 50 Hz18.5 kW
Rated operational power at AC-23A, 400 V, 50 Hz30 kW
Rated operational power at AC-23A, 500 V, 50 Hz45 kW
Rated operational power at AC-23A, 690 V, 50 Hz55 kW
Rated operational power at AC-3, 380/400 V, 50 Hz30 kW
Rated operational power at AC-3, 415 V, 50 Hz30 kW
Rated operational power at AC-3, 500 V, 50 Hz30 kW
Rated operational power at AC-3, 690 V, 50 Hz30 kW
Rated operational voltage (Ue) at AC - max690 V
Rated uninterrupted current (Iu)63 A
Uninterrupted currentRated uninterrupted current Iu is specified for max. cross-section.
FeaturesVersion as main switch; Version as maintenance-/service switch; Version as emergency stop installation; Version as safety switch
Fitted withRed rotary handle and yellow locking ring
FunctionsEmergency switching off function; Interlockable
Locking facilityLockable in the 0 (Off) position
Number of poles4
AccessoriesAuxiliary contact fitted by user.
Degree of protectionNEMA 12
Degree of protection (front side)IP65
Lifespan, mechanical100,000 Operations
Mounting methodSurface mounting
Mounting positionAs required
Operating frequency1200 Operations/h
Overvoltage categoryIII
Pollution degree3
Product CategoryMain switch
Rated impulse withstand voltage (Uimp)6000 V AC
Safe isolation440 V AC, Between the contacts, According to EN 61140
Safety parameter (EN ISO 13849-1)B10d values as per EN ISO 13849-1, table C.1
Shock resistance15 g, Mechanical, According to IEC/EN 60068-2-27, Half-sinusoidal shock 20 ms
Suitable forBranch circuits, suitable as motor disconnect, (UL/CSA); Ground mounting
Switching angle90 °
Assigned motor power at 115/120 V, 60 Hz, 1-phase3 HP
Assigned motor power at 200/208 V, 60 Hz, 1-phase7.5 HP
Assigned motor power at 200/208 V, 60 Hz, 3-phase15 HP
Assigned motor power at 230/240 V, 60 Hz, 1-phase10 HP
Assigned motor power at 230/240 V, 60 Hz, 3-phase15 HP
Assigned motor power at 460/480 V, 60 Hz, 3-phase40 HP
Assigned motor power at 575/600 V, 60 Hz, 3-phase50 HP
Rated conditional short-circuit current (Iq)4 kA (Load side); 100 kA (Supply side)
Rated short-time withstand current (Icw)1.26 kA
Short-circuit current rating (basic rating)10 kA, SCCR (UL/CSA); 150A, max. Fuse, SCCR (UL/CSA)
Short-circuit protection rating80 A gG/gL, Fuse, Contacts
Load rating1.6 x Iₑ (with intermittent operation class 12, 40 % duty factor); 2 x Iₑ (with intermittent operation class 12, 25 % duty factor); 1.3 x Iₑ (with intermittent operation class 12, 60 % duty factor)
Number of contacts in series at DC-23A, 120 V3
Number of contacts in series at DC-23A, 24 V1
Number of contacts in series at DC-23A, 48 V2
Number of contacts in series at DC-23A, 60 V2
Rated making capacity up to 690 V (cos phi to IEC/EN 60947-3)800 A
Switching capacity (auxiliary contacts, general use)10A, IU, (UL/CSA)
Switching capacity (auxiliary contacts, pilot duty)P600 (UL/CSA); A600 (UL/CSA)
Switching capacity (main contacts, general use)60 A, Rated uninterrupted current max. (UL/CSA)
Voltage per contact pair in series60 V
Screw sizeM5, Terminal screw
Terminal capacity1 x (1.5 - 25) mm², flexible with ferrules to DIN 46228; 14 - 2 AWG, solid or flexible with ferrule; 2 x (2.5 - 10) mm², solid or stranded; 1 x (2.5 - 35) mm², solid or stranded; 2 x (1.5 - 6) mm², flexible with ferrules to DIN 46228
Tightening torque26.5 lb-in, Screw terminals; 3 Nm, Screw terminals
Country of originUnited Kingdom

Properties

MOQ1

Cross-References

Attached Documents