cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Safety Switch (T5-1-102/I5/SVB)

Eaton · Switchgear & Protection · Safety Switches · Ireland · eaton.com
Part Number
T5-1-102/I5/SVB  ·  HS 8536.50
Safety Switch (T5-1-102/I5/SVB)

Technical Specifications

Manufacturer part number (MPN)T5-1-102/I5/SVB
EAN / GTIN4015082072735
Sales unitpcs
Eaton catalogue number207273
Depth280 mm
Height162 mm
Width200 mm
Weight1.642 kg
CertificationsIEC/EN 60947; IEC/EN 60204; VDE 0660; IEC/EN 60947-3
Catalog NotesRated Short-time Withstand Current (Icw) for a time of 1 second
Actuator colorRed
Actuator typeDoor coupling rotary drive
Ambient operating temperature - max40 °C
Ambient operating temperature - min-25 °C
Ambient operating temperature (enclosed) - max40 °C
Ambient operating temperature (enclosed) - min-25 °C
Climatic proofingDamp heat, cyclic, to IEC 60068-2-30; Damp heat, constant, to IEC 60068-2-78
Control circuit reliability1 failure per 100,000 switching operations statistically determined, at 24 V DC, 10 mA)
Number of auxiliary contacts (change-over contacts)0
Number of auxiliary contacts (normally closed contacts)0
Number of auxiliary contacts (normally open contacts)0
Equipment heat dissipation, current-dependent Pvid7.5 W
Heat dissipation per pole, current-dependent Pvid7.5 W
Rated operational current for specified heat dissipation (In)100 A
Rated breaking capacity at 220/230 V (cos phi to IEC 60947-3)760 A
Rated breaking capacity at 400/415 V (cos phi to IEC 60947-3)740 A
Rated breaking capacity at 500 V (cos phi to IEC 60947-3)590 A
Rated breaking capacity at 660/690 V (cos phi to IEC 60947-3)420 A
Rated operational current (Ie) at AC-21, 440 V100 A
Rated operational current (Ie) at AC-23A, 230 V100 A
Rated operational current (Ie) at AC-23A, 400 V, 415 V100 A
Rated operational current (Ie) at AC-23A, 500 V55 A
Rated operational current (Ie) at AC-23A, 690 V32 A
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V71 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V55 A
Rated operational current (Ie) at AC-3, 500 V44 A
Rated operational current (Ie) at AC-3, 660 V, 690 V17 A
Rated operational current (Ie) star-delta at AC-3, 220/230 V100 A
Rated operational current (Ie) star-delta at AC-3, 380/400 V95.3 A
Rated operational current (Ie) star-delta at AC-3, 500 V76.2 A
Rated operational current (Ie) star-delta at AC-3, 690 V29.4 A
Rated operational power at AC-23A, 220/230 V, 50 Hz30 kW
Rated operational power at AC-23A, 400 V, 50 Hz55 kW
Rated operational power at AC-23A, 500 V, 50 Hz37 kW
Rated operational power at AC-23A, 690 V, 50 Hz30 kW
Rated operational power at AC-3, 380/400 V, 50 Hz30 kW
Rated operational power at AC-3, 415 V, 50 Hz30 kW
Rated operational power at AC-3, 500 V, 50 Hz30 kW
Rated operational power at AC-3, 690 V, 50 Hz15 kW
Rated operational power star-delta at 220/230 V, 50 Hz30 kW
Rated operational power star-delta at 380/400 V, 50 Hz45 kW
Rated operational power star-delta at 500 V, 50 Hz45 kW
Rated operational power star-delta at 690 V, 50 Hz22 kW
Rated operational voltage (Ue) at AC - max690 V
Rated uninterrupted current (Iu)100 A
Uninterrupted currentRated uninterrupted current Iu is specified for max. cross-section.
FeaturesVersion as main switch; Version as maintenance-/service switch; Version as emergency stop installation
Fitted withRed rotary handle and yellow locking ring
FunctionsInterlockable; Emergency switching off function
Locking facilityLockable in the 0 (Off) position
Number of poles2
Degree of protectionNEMA 12
Degree of protection (front side)IP65
Lifespan, mechanical500,000 Operations
Mounting methodSurface mounting
Mounting positionAs required
Number of contact units1
Operating frequency1200 Operations/h
Overvoltage categoryIII
Pollution degree3
Product CategoryMain switch
Rated impulse withstand voltage (Uimp)6000 V AC
Safe isolation440 V AC, Between the contacts, According to EN 61140
Safety parameter (EN ISO 13849-1)B10d values as per EN ISO 13849-1, table C.1
Shock resistance15 g, Mechanical, According to IEC/EN 60068-2-27, Half-sinusoidal shock 20 ms
Suitable forGround mounting
Switching angle90 °
Rated conditional short-circuit current (Iq)2 kA
Rated short-time withstand current (Icw)1,7 kA, Contacts, 1 second; 1.7 kA
Short-circuit protection rating100 A gG/gL, Fuse, Contacts
Load rating2 x Iₑ (with intermittent operation class 12, 25 % duty factor); 1.3 x Iₑ (with intermittent operation class 12, 60 % duty factor); 1.6 x Iₑ (with intermittent operation class 12, 40 % duty factor)
Rated making capacity up to 690 V (cos phi to IEC/EN 60947-3)950 A
Voltage per contact pair in series60 V
Screw sizeM6, Terminal screw
Terminal capacity2 x (1.5 - 10) mm², flexible with ferrule to DIN 46228; 1 x (1 - 25) mm², flexible with ferrules to DIN 46228; 2 x (2.5 - 16) mm², solid or stranded; 1 x (2.5 - 35) mm², solid or stranded
Tightening torque4 Nm, Screw terminals; 35.4 lb-in, Screw terminals
Country of originUnited Kingdom

Properties

MOQ1

Cross-References

Attached Documents