cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Safety Switch (P1-32/EA/SVB/N)

Eaton · Switchgear & Protection · Disconnect Switches · Ireland · eaton.com
Part Number
P1-32/EA/SVB/N  ·  HS 8536.50
Safety Switch (P1-32/EA/SVB/N)

Technical Specifications

Manufacturer part number (MPN)P1-32/EA/SVB/N
EAN / GTIN4015080910794
Sales unitpcs
Eaton catalogue number091079
Depth120 mm
Height70 mm
Width65 mm
Weight0.222 kg
CertificationsCSA Class No.: 3211-05; VDE 0660; UL; UL Category Control No.: NLRV; UL 60947-4-1; CSA; IEC/EN 60947; IEC/EN 60947-3; CSA-C22.2 No. 60947-4-1-14; IEC/EN 60204; CE; UL File No.: E36332; CSA File No.: 012528; CSA-C22.2 No. 94
Catalog NotesRated Short-time Withstand Current (Icw) for a time of 1 second
Actuator colorRed
Actuator typeDoor coupling rotary drive
Ambient operating temperature - max50 °C
Ambient operating temperature - min-25 °C
Ambient operating temperature (enclosed) - max40 °C
Ambient operating temperature (enclosed) - min-25 °C
Climatic proofingDamp heat, cyclic, to IEC 60068-2-30; Damp heat, constant, to IEC 60068-2-78
Control circuit reliability1 failure per 100,000 switching operations statistically determined, at 24 V DC, 10 mA)
Number of auxiliary contacts (change-over contacts)0
Number of auxiliary contacts (normally closed contacts)0
Number of auxiliary contacts (normally open contacts)0
Heat dissipation per pole, current-dependent Pvid1.8 W
Rated operational current for specified heat dissipation (In)32 A
Rated breaking capacity at 220/230 V (cos phi to IEC 60947-3)260 A
Rated breaking capacity at 400/415 V (cos phi to IEC 60947-3)300 A
Rated breaking capacity at 500 V (cos phi to IEC 60947-3)290 A
Rated breaking capacity at 660/690 V (cos phi to IEC 60947-3)250 A
Rated operational current (Ie) at AC-21, 440 V32 A
Rated operational current (Ie) at AC-23A, 230 V32 A
Rated operational current (Ie) at AC-23A, 400 V, 415 V32 A
Rated operational current (Ie) at AC-23A, 500 V30 A
Rated operational current (Ie) at AC-23A, 690 V19.8 A
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V26.4 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V26.4 A
Rated operational current (Ie) at AC-3, 500 V23.4 A
Rated operational current (Ie) at AC-3, 660 V, 690 V14.7 A
Rated operational current (Ie) at DC-23A, 120 V12 A
Rated operational current (Ie) at DC-23A, 24 V25 A
Rated operational current (Ie) at DC-23A, 48 V25 A
Rated operational current (Ie) at DC-23A, 60 V25 A
Rated operational power at AC-23A, 220/230 V, 50 Hz7.5 kW
Rated operational power at AC-23A, 400 V, 50 Hz15 kW
Rated operational power at AC-23A, 500 V, 50 Hz18.5 kW
Rated operational power at AC-23A, 690 V, 50 Hz15 kW
Rated operational power at AC-3, 380/400 V, 50 Hz13 kW
Rated operational power at AC-3, 415 V, 50 Hz13 kW
Rated operational power at AC-3, 500 V, 50 Hz18.5 kW
Rated operational power at AC-3, 690 V, 50 Hz15 kW
Rated operational voltage (Ue) at AC - max690 V
Rated uninterrupted current (Iu)32 A
Uninterrupted currentRated uninterrupted current Iu is specified for max. cross-section.
FeaturesVersion as main switch; Version as emergency stop installation; Version as maintenance-/service switch
Fitted withRed rotary handle and yellow locking ring
FunctionsEmergency switching off function; Interlockable
Locking facilityLockable in the 0 (Off) position
Number of poles4
AccessoriesAuxiliary contact fitted by user.
Degree of protectionNEMA 12
Degree of protection (front side)IP65
Lifespan, mechanical300,000 Operations
Mounting methodFlush mounting
Mounting positionAs required
Operating frequency1200 Operations/h
Overvoltage categoryIII
Pollution degree3
Product CategoryMain switch
Rated impulse withstand voltage (Uimp)6000 V AC
Safe isolation440 V AC, Between the contacts, According to EN 61140
Safety parameter (EN ISO 13849-1)B10d values as per EN ISO 13849-1, table C.1
Shock resistance15 g, Mechanical, According to IEC/EN 60068-2-27, Half-sinusoidal shock 20 ms
Suitable forFront mounting 4-hole; Branch circuits, suitable as motor disconnect, (UL/CSA)
Assigned motor power at 115/120 V, 60 Hz, 1-phase1 HP
Assigned motor power at 200/208 V, 60 Hz, 1-phase2 HP
Assigned motor power at 200/208 V, 60 Hz, 3-phase3 HP
Assigned motor power at 230/240 V, 60 Hz, 1-phase3 HP
Assigned motor power at 230/240 V, 60 Hz, 3-phase7.5 HP
Assigned motor power at 460/480 V, 60 Hz, 3-phase10 HP
Assigned motor power at 575/600 V, 60 Hz, 3-phase15 HP
Rated conditional short-circuit current (Iq)80 kA
Rated short-time withstand current (Icw)640 A, Contacts, 1 second; 0.64 kA
Short-circuit current rating (basic rating)110A, max. Fuse, SCCR (UL/CSA); 5 kA, SCCR (UL/CSA)
Short-circuit current rating (high fault)50 A, Class J, max. Fuse, SCCR (UL/CSA); 10 kA, SCCR (UL/CSA)
Short-circuit protection rating50 A gG/gL, Fuse, Contacts
Load rating1.6 x Iₑ (with intermittent operation class 12, 40 % duty factor); 1.3 x Iₑ (with intermittent operation class 12, 60 % duty factor); 2 x Iₑ (with intermittent operation class 12, 25 % duty factor)
Number of contacts in series at DC-23A, 120 V3
Number of contacts in series at DC-23A, 24 V1
Number of contacts in series at DC-23A, 48 V2
Number of contacts in series at DC-23A, 60 V2
Rated making capacity up to 690 V (cos phi to IEC/EN 60947-3)320 A
Switching capacity (auxiliary contacts, general use)10A, IU, (UL/CSA)
Switching capacity (auxiliary contacts, pilot duty)A600 (UL/CSA); P600 (UL/CSA)
Switching capacity (main contacts, general use)30 A, Rated uninterrupted current max. (UL/CSA)
Voltage per contact pair in series60 V
Screw sizeM4, Terminal screw
Terminal capacity2 x (1.5 - 6) mm², solid or stranded; 1 x (1.5 - 6) mm², solid or stranded; 14 - 8 AWG, solid or flexible with ferrule; 2 x (1 - 4) mm², flexible with ferrules to DIN 46228; 1 x (1 - 4) mm², flexible with ferrules to DIN 46228
Tightening torque1.6 Nm, Screw terminals; 14.1 lb-in, Screw terminals
Country of originUnited Kingdom

Properties

MOQ1

Cross-References

Attached Documents