| Manufacturer part number (MPN) | P1-40/I2H |
| EAN / GTIN | 4015082953393 |
| HS code | 8536.90 |
| Sales unit | pcs |
| Eaton catalogue number | 199915 |
| Depth | 107 mm |
| Height | 180 mm |
| Width | 100 mm |
| Weight | 0.534 kg |
| Compliances | UKCA; CE |
| Certifications | IEC/EN 60947; IEC/EN 60947-3; IEC/EN 60204 |
| Catalog Notes | Rated Short-time Withstand Current (Icw) for a time of 1 second |
| Actuator color | Black |
| Actuator type | Short thumb-grip |
| Ambient operating temperature - max | 40 °C |
| Ambient operating temperature - min | -25 °C |
| Ambient operating temperature (enclosed) - max | 40 °C |
| Ambient operating temperature (enclosed) - min | -25 °C |
| Climatic proofing | Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclic, to IEC 60068-2-30 |
| Control circuit reliability | 1 failure per 100,000 switching operations statistically determined, at 24 V DC, 10 mA) |
| Number of auxiliary contacts (change-over contacts) | 0 |
| Number of auxiliary contacts (normally closed contacts) | 0 |
| Number of auxiliary contacts (normally open contacts) | 0 |
| Equipment heat dissipation, current-dependent Pvid | 0 W |
| Heat dissipation capacity Pdiss | 0 W |
| Heat dissipation per pole, current-dependent Pvid | 3.5 W |
| Rated operational current for specified heat dissipation (In) | 40 A |
| Static heat dissipation, non-current-dependent Pvs | 0 W |
| Rated breaking capacity at 400/415 V (cos phi to IEC 60947-3) | 290 kA |
| Rated breaking capacity at 660/690 V (cos phi to IEC 60947-3) | 130 kA |
| Rated operational current (Ie) at AC-21, 440 V | 40 A |
| Rated operational current (Ie) at AC-23A, 230 V | 40 A |
| Rated operational current (Ie) at AC-23A, 400 V, 415 V | 40 A |
| Rated operational current (Ie) at AC-23A, 690 V | 20 A |
| Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V | 30 A |
| Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V | 30 A |
| Rated operational current (Ie) at AC-3, 660 V, 690 V | 17 A |
| Rated operational power at AC-23A, 220/230 V, 50 Hz | 11 kW |
| Rated operational power at AC-23A, 400 V, 50 Hz | 22 kW |
| Rated operational power at AC-23A, 690 V, 50 Hz | 18.5 kW |
| Rated operational power at AC-3, 380/400 V, 50 Hz | 15 kW |
| Rated operational power at AC-3, 415 V, 50 Hz | 15 kW |
| Rated operational power at AC-3, 690 V, 50 Hz | 15 kW |
| Rated operational voltage (Ue) at AC - max | 690 V |
| Rated uninterrupted current (Iu) | 40 A |
| Uninterrupted current | Rated uninterrupted current Iu is specified for max. cross-section. |
| Enclosure material | Polycarbonate |
| Fitted with | Black thumb grip and front plate; Auxiliary contact |
| Number of poles | 3 |
| Degree of protection | IP65 |
| Degree of protection (front side) | IP65 |
| Lifespan, mechanical | 300,000 Operations |
| Mounting method | Surface mounting |
| Mounting position | As required |
| Operating frequency | 50 Operations/h |
| Overvoltage category | III |
| Pollution degree | 3 |
| Product Category | On-Off switch |
| Rated impulse withstand voltage (Uimp) | 6000 V AC |
| Safe isolation | 440 V AC, Between the contacts, According to EN 61140 |
| Shock resistance | 15 g, Mechanical, According to IEC/EN 60068-2-27, Half-sinusoidal shock 20 ms |
| Switching angle | 90 ° |
| Rated conditional short-circuit current (Iq) | 80 kA |
| Rated short-time withstand current (Icw) | 0.64 kA; 640 A, Contacts, 1 second |
| Short-circuit protection rating | 50 A gG/gL, Fuse, Contacts |
| Load rating | 1.3 x Iₑ (with intermittent operation class 12, 60 % duty factor); 1.6 x Iₑ (with intermittent operation class 12, 40 % duty factor); 2 x Iₑ (with intermittent operation class 12, 25 % duty factor) |
| Screw size | M4, Terminal screw |
| Terminal capacity | 1 x (1 - 4) mm², flexible with ferrules to DIN 46228; 2 x (1 - 4) mm², flexible with ferrules to DIN 46228; 1 x 10 mm² with fork terminal; 2 x 10 mm² with fork terminal |
| Tightening torque | 1.6 Nm, Screw terminals |