cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

EMC Serviceswitch IP65 (T0-3-15680/I2H/MBS/SVB-SW)

Eaton · Switchgear & Protection · Disconnect Switches · Ireland · eaton.com
Part Number
T0-3-15680/I2H/MBS/SVB-SW  ·  HS 8536.50
EMC Serviceswitch IP65 (T0-3-15680/I2H/MBS/SVB-SW)

Eaton T0-3-15680/I2H/MBS/SVB-SW T0-3-15680/I2H/MBS/SVB-SW.

Technical Specifications

Manufacturer part number (MPN)T0-3-15680/I2H/MBS/SVB-SW
EAN / GTIN4015081773589
Sales unitpcs
Eaton catalogue number182432
Depth136 mm
Height181 mm
Width100 mm
Weight0.575 kg
CertificationsIEC/EN 60947; IEC/EN 60204; VDE 0660; IEC/EN 60947-3
Actuator colorBlack
Actuator typeDoor coupling rotary drive
Ambient operating temperature - max40 °C
Ambient operating temperature - min-25 °C
Ambient operating temperature (enclosed) - max40 °C
Ambient operating temperature (enclosed) - min-20 °C
Climatic proofingDamp heat, cyclic, to IEC 60068-2-30; Damp heat, constant, to IEC 60068-2-78
Control circuit reliability1 failure per 100,000 switching operations statistically determined, at 24 V DC, 10 mA)
Number of auxiliary contacts (change-over contacts)0
Number of auxiliary contacts (normally closed contacts)1
Number of auxiliary contacts (normally open contacts)1
Heat dissipation per pole, current-dependent Pvid0.6 W
Rated operational current for specified heat dissipation (In)20 A
Rated breaking capacity at 220/230 V (cos phi to IEC 60947-3)100 A
Rated breaking capacity at 400/415 V (cos phi to IEC 60947-3)110 A
Rated breaking capacity at 500 V (cos phi to IEC 60947-3)80 A
Rated breaking capacity at 660/690 V (cos phi to IEC 60947-3)60 A
Rated operational current (Ie) at AC-21, 440 V20 A
Rated operational current (Ie) at AC-23A, 230 V13.3 A
Rated operational current (Ie) at AC-23A, 400 V, 415 V13.3 A
Rated operational current (Ie) at AC-23A, 500 V13.3 A
Rated operational current (Ie) at AC-23A, 690 V7.6 A
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V11.5 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V11.5 A
Rated operational current (Ie) at AC-3, 500 V9 A
Rated operational current (Ie) at AC-3, 660 V, 690 V4.9 A
Rated operational current (Ie) at DC-13, control switches L/R = 50 ms10 A
Rated operational current (Ie) at DC-21, 240 V1 A
Rated operational current (Ie) at DC-23A, 120 V5 A
Rated operational current (Ie) at DC-23A, 24 V10 A
Rated operational current (Ie) at DC-23A, 240 V5 A
Rated operational current (Ie) at DC-23A, 48 V10 A
Rated operational current (Ie) at DC-23A, 60 V10 A
Rated operational current (Ie) star-delta at AC-3, 220/230 V20 A
Rated operational current (Ie) star-delta at AC-3, 380/400 V20 A
Rated operational current (Ie) star-delta at AC-3, 500 V15.6 A
Rated operational current (Ie) star-delta at AC-3, 690 V8.5 A
Rated operational power at AC-23A, 220/230 V, 50 Hz3 kW
Rated operational power at AC-23A, 400 V, 50 Hz5.5 kW
Rated operational power at AC-23A, 500 V, 50 Hz7.5 kW
Rated operational power at AC-23A, 690 V, 50 Hz5.5 kW
Rated operational power at AC-3, 380/400 V, 50 Hz5.5 kW
Rated operational power at AC-3, 415 V, 50 Hz5.5 kW
Rated operational power at AC-3, 690 V, 50 Hz4 kW
Rated operational power star-delta at 220/230 V, 50 Hz5.5 kW
Rated operational power star-delta at 380/400 V, 50 Hz7.5 kW
Rated operational power star-delta at 500 V, 50 Hz7.5 kW
Rated operational power star-delta at 690 V, 50 Hz5.5 kW
Rated operational voltage (Ue) at AC - max690 V
Rated uninterrupted current (Iu)20 A
Uninterrupted currentRated uninterrupted current Iu is specified for max. cross-section.
FeaturesVersion as main switch; Version as maintenance-/service switch
Fitted withBlack rotary handle and locking ring; Assembly sheet screen
FunctionsSTOP function; Interlockable
Locking facilityLockable in the 0 (Off) position
Number of poles4
Degree of protectionNEMA 12
Degree of protection (front side)IP65
Lifespan, mechanical400,000 Operations
Mounting methodSurface mounting
Mounting positionAs required
Number of contact units3
Operating frequency1200 Operations/h
Overvoltage categoryIII
Pollution degree3
Product CategoryMain switch
Rated impulse withstand voltage (Uimp)6000 V AC
Safe isolation440 V AC, Between the contacts, According to EN 61140
Safety parameter (EN ISO 13849-1)B10d values as per EN ISO 13849-1, table C.1
Shock resistance15 g, Mechanical, According to IEC/EN 60068-2-27, Half-sinusoidal shock 20 ms
Suitable forGround mounting
Switching angle90 °
Rated conditional short-circuit current (Iq)6 kA
Rated short-time withstand current (Icw)0.32 kA; 320 A, Contacts, 1 second
Short-circuit protection rating20 A gG/gL, Fuse, Contacts
Load rating1.3 x Iₑ (with intermittent operation class 12, 60 % duty factor); 2 x Iₑ (with intermittent operation class 12, 25 % duty factor); 1.6 x Iₑ (with intermittent operation class 12, 40 % duty factor)
Number of contacts in series at DC-21A, 240 V1
Number of contacts in series at DC-23A, 120 V3
Number of contacts in series at DC-23A, 24 V1
Number of contacts in series at DC-23A, 240 V5
Number of contacts in series at DC-23A, 48 V2
Number of contacts in series at DC-23A, 60 V3
Rated making capacity up to 690 V (cos phi to IEC/EN 60947-3)130 A
Voltage per contact pair in series60 V
Screw sizeM3.5, Terminal screw
Terminal capacity1 x (1 - 2.5) mm², solid or stranded; 2 x (1 - 2.5) mm², solid or stranded; 1 x (0.75 - 2.5) mm², flexible with ferrules to DIN 46228; 2 x (0.75 - 2.5) mm², flexible with ferrules to DIN 46228
Tightening torque1 Nm, Screw terminals
Country of originUnited Kingdom

Properties

MOQ1

Cross-References