cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-08
sales@cballast.com
cballast.com

Danfoss RAS-D2 Radiator Pack radiator valve set (TRV set) — Straight 10/15 mm, 3-Elements, RAS-D2 sensor (013G6018)

Danfoss · HVAC & Refrigeration · Radiator Valves · Denmark · danfoss.com
Part Number
013G6018  ·  HS 8481.80
Danfoss RAS-D2 Radiator Pack radiator valve set (TRV set) — Straight 10/15 mm, 3-Elements, RAS-D2 sensor (013G6018)

Danfoss RAS-D2 Radiator Pack thermostatic radiator valve set (TRV set), OEM order code 013G6018 — a matched 3-elements package for a single radiator: Includes RAS-D2 sensor, RA-FS 15 mm bi-directional straight valve, lockshield valve, 10/15 mm fittings and Allen key for fixing sensor. Straight pattern, valve size 10/15 mm. The RAS-D2 sensor is liquid-charged and self-acting (setting range 8–28 °C, no power or wiring); the RLV-D return/lockshield valve allows the radiator to be balanced and isolated for service. Genuine Danfoss parts; technical data quoted verbatim from store.danfoss.com (code 013G6018). OEM P/N 013G6018, EAN 5702420063485. Used in commercial refrigeration, provision-room cooling and reefer plant rooms across HFC, HFO and CO2 (R744) refrigerants.

Technical Specifications

Code number013G6018
BrandDanfoss
TypeRAS-D2 Radiator Pack
Product groupTRV set
Set contents3-elements — Includes RAS-D2 sensor, RA-FS 15 mm bi-directional straight valve, lockshield valve, 10/15 mm fittings and Allen key for fixing sensor
DesignStraight
Valve size10/15 mm
Valve typeBi-directional (RA-FS)
Lockshield / return valve typeRLV-D
Sensor-to-valve connectionRA
Sensor designRAS-D2 (liquid-charged, self-acting)
Sensor temperature setting range8 °C to 28 °C
Sensor response time24 min
Zero-blocking (positive shut-off)Yes
TailpieceChrome-plated
ColourChrome
REACH candidate-list substancesLead (CAS no. 7439-92-1)
Net weight537 Gram
EAN5702420063485
HS code8481.80 (taps, cocks, valves)

Properties

MaterialNickel-plated brass valve body; liquid-charged polymer thermostatic sensor
Temperature rangesensor setting 8 °C to 28 °C
MOQ1

Compatibility

Complete straight-pattern TRV set for a 10/15 mm radiator connection (RA sensor fixing). Supplied as 3-elements: Includes RAS-D2 sensor, RA-FS 15 mm bi-directional straight valve, lockshield valve, 10/15 mm fittings and Allen key for fixing sensor. Confirm radiator tapping size (10/15 mm) and flow/return pattern (Straight) before ordering; the set components are matched and not individually substituted.

Attached Documents