Danfoss RAS-C + RA-FN + RLV-S thermostatic radiator valve set (TRV set), OEM order code 013G5254 — a matched 3-elements package for a single radiator: PANDA-RA + RA-FN + RLV-S. Straight pattern, valve size DN 15. The RAS-C sensor is liquid-charged and self-acting (setting range 8–28 °C °C, no power or wiring); the RLV-S return valve allows the radiator to be balanced and isolated for service. Genuine Danfoss parts; technical data quoted verbatim from store.danfoss.com (code 013G5254). OEM P/N 013G5254, EAN 5702425099007. HS 8481.80.
| Code number | 013G5254 |
| Brand | Danfoss |
| Type | RAS-C + RA-FN + RLV-S |
| Product group | TRV set |
| Set contents | 3-elements — PANDA-RA + RA-FN + RLV-S |
| Design | Straight |
| Valve size | DN 15 |
| Valve type | RA-FN |
| Lockshield / return valve type | RLV-S |
| Sensor-to-valve connection | RA |
| Sensor design | RAS-C (liquid-charged, self-acting) |
| Sensor temperature setting range | 8 °C to 28 °C |
| Tailpiece | Standard |
| Colour | Black RAL 9005 / White RAL 9016 |
| REACH candidate-list substances | Lead (CAS no. 7439-92-1) |
| Net weight | 0.648 kg |
| EAN | 5702425099007 |
| HS code | 8481.80 (taps, cocks, valves) |
| CE mark | No |
| China RoHS compliance | Out of scope |
| Connection type to valve | RA |
| Contents of set | 3-elements |
| Description | PANDA-RA + RA-FN + RLV-S |
| EU RoHS compliance | Yes with exemptions |
| EU RoHS exemption clause | 6(c) |
| Packaging type | Box |
| RLV type | RLV-S |
| Sensor media | Liquid |
| Sensor setting temperature [°C] [Max] | 28 °C |
| Sensor setting temperature [°C] [Min] | 8 °C |
| Sensor type | Built-in sensor |
| Tailpiece type | Standard |
| UL mark | No |
| UNSPSC CODE | 40101801 |
| Material | Nickel-plated brass valve body; liquid-charged polymer thermostatic sensor |
| Temperature range | sensor setting 8 °C to 28 °C |
| MOQ | 1 |
Complete straight-pattern TRV set for a DN 15 radiator connection (RA sensor fixing). Supplied as 3-elements: PANDA-RA + RA-FN + RLV-S. Confirm radiator tapping size (DN 15) and flow/return pattern (Straight) before ordering; the set components are matched and not individually substituted.