Danfoss SAVD (003H6694) — self-acting safety pressure reduction controller, PN 25, DN 20, for district heating and central heating systems. The SAVD is a safety pressure reduction controller that needs no external power or control signal; the setpoint is set on the actuator spring and the reduced/relieved pressure is sensed through an impulse line to the control diaphragm. It is normally open and closes progressively as the downstream (outlet) pressure rises, holding the reduced pressure at or below the setpoint to protect equipment against over-pressure. Pressure setting range 1 – 5 bar adjustable; Kvs 6.3 m³/h; maximum differential-pressure range 20 bar; media temperature 2–150 °C; cavitation factor z ≥ 0.6; seat leakage 0.02 % Kvs (IEC 60534). Valve body Red bronze CuSn5ZnPb (Rg5); valve cone dezincing-free brass CuZn36Pb2As; seat stainless steel 1.4571; control diaphragm EPDM. External-thread connection G 1 A (ISO 228/1) via tailpieces (tailpiece/union-nut set ordered separately). Media: district heating/cooling circulation water (glycolic water up to 30%), pH 7–10. Mounting version Free; stem position Normally open. OEM P/N 003H6694. EAN 5702421542156. Technical data quoted verbatim from store.danfoss.com (code 003H6694).
| Code number | 003H6694 |
| Type | SAVD |
| Product group | Pressure and flow controllers (safety pressure controller) |
| Function | Self-acting safety pressure reduction controller (SAV) — normally open, closes on rising downstream pressure to hold a limited reduced (outlet) pressure |
| Valve size | DN 20 |
| Pressure class | PN 25 |
| Connection | External thread G 1 A (ISO 228/1), via tailpieces |
| Kvs value | 6.3 m³/h |
| Pressure setting range | 1 – 5 bar (adjustable) |
| Max. differential pressure range | 20 bar |
| Media temperature | 2 – 150 °C |
| Media pH | 7 – 10 |
| Cavitation factor z | ≥ 0.6 |
| Seat leakage rate | 0.02 % Kvs (IEC 60534) |
| Mounting version | Free |
| Stem position | Normally open |
| Number of ports | 2 |
| Permissible media | District heating/cooling circulation water (glycolic water up to 30%) |
| Valve body material | Red bronze CuSn5ZnPb (Rg5) |
| Valve cone material | Dezincing free brass CuZn36Pb2As |
| Valve seat material | Stainless steel, mat. No. 1.4571 |
| Actuator diaphragm | EPDM |
| EU RoHS compliance | Yes with exemptions (6(c)) |
| REACH Candidate List substance | Lead (CAS no. 7439-92-1) |
| China RoHS | Out of scope |
| Net weight | 5.424 kg |
| Gross weight | 5.424 kg |
| EAN | 5702421542156 |
| HS code | 8481.80 |
| Material | Valve body Red bronze CuSn5ZnPb (Rg5); valve cone dezincing-free brass CuZn36Pb2As; seat stainless steel, mat. No. 1.4571; control diaphragm + DP sealing EPDM |
| Pressure rating | PN 25 (max. differential-pressure range 20 bar) |
| Temperature range | 2 to 150 °C (district heating/cooling water); glycolic water up to 30% |
| MOQ | 1 |
Danfoss SAVD for DN 20 district-heating/central-heating circuits at PN 25 where automatic over-pressure protection is required by limiting the reduced downstream pressure. Set the reduction setpoint within 1 – 5 bar; for a different band use the higher-range SAVD. Size the valve by the design flow against Kvs 6.3 m³/h. Confirm the connection (External thread G 1 A (ISO 228/1), via tailpieces) and pressure class (PN 25) match the pipework; order the matching tailpiece/union-nut set and impulse tube separately. Maximum differential-pressure range 20 bar, media temperature up to 150 °C. For pressure RELIEF use the SAVA; for combined differential-pressure and flow control use the AVPQ.