cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Danfoss RT260A Differential Pressure Switch 0.5 to 6 bar SPDT Auto Reset (017D002366)

Danfoss · Sensors & Instrumentation · Pressure Sensors · Denmark · danfoss.com
Part Number
017D002366  ·  HS 9032.20
Danfoss RT260A Differential Pressure Switch 0.5 to 6 bar SPDT Auto Reset (017D002366)

Danfoss RT260A mechanical differential pressure switch with single-pole double-throw (SPDT) contact and auto reset. Differential setting range 0.5 to 6 bar; maximum working pressure 42 bar; G 3/8 male pressure connection (ISO 228-1); enclosure IP66. Danfoss code number 017D002366.

Technical Specifications

BrandDanfoss
ModelRT260A differential pressure switch
Code number017D002366
Differential setting range0.5 to 6 bar
Maximum working pressure42 bar
Contact functionSPDT (single-pole double-throw)
ResetAuto
Differential0.5 bar (contact differential)
Pressure sensing elementbellows
Pressure connectionG 3/8 male (ISO 228-1)
EnclosureIP66
Ambient temperature range-50 to +70 degC (-58 to +158 degF)
Cable entry2 x Pg 13.5
Maximum test pressure47 bar
EAN5702428042826
StandardsEN 60947-4, EN 60947-5
ApprovalsCE, EAC, CCC, RINA, RMRS, KR, CMIM, LVD
Net weight0.994 Kilogram
TypeRT260A
Product groupSwitches and thermostats
Ambient temperature range [°C] [max]70 °C
Ambient temperature range [°C] [min]-50 °C
Ambient temperature range [°F] [max]158 °F
Ambient temperature range [°F] [min]-58 °F
ApprovalCCC
CE markYes
China RoHS complianceYes
Contact differential [bar]0.5 bar
Contact ratingAC15=3 A, 400 V
Diff.press.setting range [bar] [max]6 bar
Diff.press.setting range [bar] [min]0.5 bar
Diff.press.setting range [MPa] [max]0.6 MPa
Diff.press.setting range [MPa] [min]0.05 MPa
Diff.press.setting range [psi] [max]87 psi
Diff.press.setting range [psi] [min]7.3 psi
EEE category5 small equipment (any external dimension < 50 cm)
Electrical conn
Male/FemaleFemale
Electrical connectionScrewed cable entry
Electrical connection size2xPg 13.5
Electrical connection standardDIN 40430
Electrical spec. standardEN 60947-4/-5
EN 60947 electrical propertiesInsulation: 400V
EN 60947 wiring propertiesFlex, ferrules: 0.2-1.5 mm2
Enclosure rating IPIP66
EU RoHS complianceYes
In scope of WEEEYes
Max. test pressure [bar] Pe47 bar
Max. test pressure [psig]681 psig
Max. Working Pressure [bar]42 bar
Max. Working Pressure [psig]609 psig
Operat. range LP side [bar] Pe [max]36 bar
Operat. range LP side [bar] Pe [min]-1 bar
Operat. range LP side [psig]Pe [max]522 psig
Operat. range LP side [psig]Pe [min]-15 psig
Other RoHS documentationSaudi Arabia RoHS
Pressure connection notesWeld nipple d6.5/D10mm
Pressure connection size3/8
Pressure connection standardISO 228-1
Pressure connection typeG
Pressure Male/FemaleMale
Pressure range [bar] Pe [max]36 bar
Pressure range [bar] Pe [min]-1 bar
REACH Candidate List substancesLead (CAS no. 7439-92-1)
RefrigerantsR11
Relay release time [s]0 s
Reset functionAuto
UL approved refrigerantsR11

Properties

MaterialBellows sensing element
Pressure rating42 bar
Temperature range-50 to +70 degC
IP ratingIP66
Primary standardEN 60947-5
Thread standardISO 228-1
MOQ1

Compatibility

G 3/8 male (ISO 228-1) pressure connection. Confirm range and reset type against application.

Standards

Approvals

Attached Documents