Danfoss RAS-D Sensors thermostatic radiator sensor, OEM order code 013G5022 — a remote (off-valve) thermostatic operator: the liquid-charged sensing bulb reads the room air and is linked to the valve head by a 2 m capillary tube, for radiators that are boxed in, curtained or close to the floor. It fits Danfoss RA radiator valves via the RA connection (ra-click fixing) and needs no wiring or batteries. Temperature setting range 8 °C to 28 °C; sensing charge liquid; housing colour White RAL 9016. The head provides built-in frost protection (holds a minimum setting at the snowflake position), maximum/minimum temperature limiting and set-point locking with concealed pins under the dial. Genuine Danfoss part; technical data quoted verbatim from store.danfoss.com (code 013G5022). OEM P/N 013G5022, EAN 5702420020761. HS 9032.10 (thermostats).
| Code number | 013G5022 Brand: Danfoss Type: RAS-D Sensors Product group: Radiator Sensors Sensor version: RAS-D 5022 Sensor design: RAS-D Function: Self-acting thermostatic radiator operator (sensor head) Sensor charge medium: Liquid (self-acting, no power) Sensor type: Remote sensor Temperature setting range: 8 °C to 28 °C Connection to valve: RA Sensor / adjuster connection: RA-click Capillary (remote) tube length: 2 m Frost protection: Yes Temperature limiting & locking: Yes Shut-off (0 / closed) position: No Colour: White RAL 9016 Feature description: Temperature limitation feature CE mark: No EU RoHS compliance: Yes with exemptions REACH candidate-list substances: Lead (CAS no. 7439-92-1) Net weight: 0.224 kg Gross weight: 0.23 kg EAN: 5702420020761 HS code: 9032.10 (thermostats) |
| Material | Housing polymer (White RAL 9016); liquid-charged thermostatic sensing element |
| Temperature range | setting 8 °C to 28 °C |
| MOQ | 1 |
Thermostatic operator head for Danfoss RA radiator valves (RA valve connection). Route the 2 m capillary and fix with the clamping ring / nut supplied. Confirm the valve connection (RA) before ordering. Self-acting — no power supply required. Setting range 8 °C–28 °C.