Danfoss MBT 5560 temperature transmitter, Pt 1000 with built-in 4-20 mA transmitter, 50 mm insertion, M14 x 1.5 process connection (code 084Z4125)

Danfoss · Sensors & Instrumentation · Temperature Sensors · Denmark · danfoss.com
Part Number
084Z4125  ·  HS 9025.19
Danfoss MBT 5560 temperature transmitter, Pt 1000 with built-in 4-20 mA transmitter, 50 mm insertion, M14 x 1.5 process connection (code 084Z4125)

Danfoss MBT 5560 insertion temperature transmitter, code 084Z4125 (type designation MBT 5560-0000-0050-1B-815). Compact temperature sensor with integrated 2-wire transmitter that converts the resistance of a built-in Pt 1000 platinum element into a standardized 4-20 mA (2-wire) signal, so a defined temperature span is transmitted directly without a separate head or rail transmitter. For engine cooling water, lubricating and hydraulic oil, compressor and HVAC/R circuits, and marine and industrial plant. Insertion length 50 mm; M14 x 1.5 male process connection (ISO 965); AISI 316 Ti stainless-steel protection tube, 8 mm. Measuring range -50 to +200 C (-58 to +392 F). Output 4-20 mA (2-wire); supply 10-32 V DC. Electrical connection: Angular connector, Pg 9 (EN 175301-803-A). IP65 enclosure per IEC 60529. Supplied in a 13-piece multipack. CE marked.

Technical Specifications

TypeMBT 5560 temperature transmitter (sensor with built-in transmitter)
Type designationMBT 5560-0000-0050-1B-815
Code number084Z4125
Sensor elementPt 1000 platinum resistance (1000 ohm at 0 C), EN 60751
Measuring range-50 to +200 C (-58 to +392 F)
Output signal4-20 mA (2-wire)
Supply voltage10-32 V DC
Insertion length50 mm
Process connectionM14 x 1.5 male, ISO 965
Protection tubeAISI 316 Ti stainless steel, 8 mm dia.
Electrical connectionAngular connector, Pg 9 (EN 175301-803-A)
Enclosure ratingIP65 per IEC 60529
Net weight0.112 kg
Packing formatMulti pack (13 pc)
ApprovalsCE
EAN5702428400688
Product groupSensors
Ambient temperature max. [°C]85 °C
Ambient temperature max. [°F]185 °F
ApprovalCE
CE markYes
China RoHS complianceOut of scope
Connection materialAISI 316 Ti
Connection standardISO 228
Connection typeM
EEE category5 small equipment (any external dimension < 50 cm)
Electrical conn
Male/FemaleMale and Female
Electrical connection sizePg 9
Electrical connection standardEN 175301-803-A
Enclosure rating IPIP65
EU RoHS complianceYes with exemptions
EU RoHS exemption clause6(c)
In scope of WEEENo
Insertion length [in]1.97 in
Insertion length [mm]50 mm
Insertion typeFixed
Output signal [mA] [max]20 mA
Output signal [mA] [min]4 mA
Process connection Male/FemaleMale
Process connection materialStainless steel
Process connection size14x1.5
Process connection standardISO 965
Process connection typeM
Protection tube diameter [in]0.315 in
Protection tube diameter [mm]8 mm
Protection tube materialAISI 316 TI
REACH Candidate List substancesLead (CAS no. 7439-92-1)
Sensor elem. resistance [Ohm]1000 Ohm
Sensor element tolerance< ± 1% FS
Sensor element typePt
Sensor InsertFixed
Supply voltage [V] DC [max]32 V
Supply voltage [V] DC [min]10 V
Temperature range [°C] [max]200 °C
Temperature range [°C] [min]-50 °C
Temperature range [°F] [max]392 °F
Temperature range [°F] [min]-58 °F
Transmitter setting range [°C] [max]150 °C
Transmitter setting range [°C] [min]-40 °C
Transmitter setting range [°F] [max]302 °F
Transmitter setting range [°F] [min]-40 °F
Transmitter typeIntegrated

Properties

MaterialAISI 316 Ti stainless steel
Temperature range-50 to +200 C
IP ratingIP65
Standard size50 mm insertion
Thread standardISO 965
MOQ1

Compatibility

MBT 5560 sensor with factory built-in transmitter — the 4-20 mA (2-wire) span is preset by the type designation and is not field-rangeable on the standard version. Confirm the required insertion length (50 mm), process thread (M14 x 1.5), output (4-20 mA (2-wire)) and supply (10-32 V DC) match the pocket/thermowell and controller input before ordering. A matching thermowell can be ordered separately.

Standards

Approvals