Danfoss MBT 5113 high-temperature transmitter with an integral Type K (NiCr-Ni) thermocouple element and a galvanically isolated 4-20 mA output for measurements up to +800 C, code 084Z7032 (type designation MBT 5113-B002-110-10-B180). Element: 1 x NiCr-Ni thermocouple, Type K, Class 2 per EN 60584-2. Insertion length 110 mm insertion; G 3/4 (ISO 228-1-A) process connection; AISI 316 Ti stainless steel, 14-24 mm diameter. Measuring/temperature span -50 to +800 C (-58 to +1472 F); output 4-20 mA (supply 8-35 V DC). Electrical connection: Type B connection head, Pg 16. Enclosure IP65 per IEC 60529. CE marked. Galvanically isolated head-mounted transmitter with exchangeable sensor insert; extension length 100 mm.
| Type | MBT 5113 (temperature transmitter) |
| Type designation | MBT 5113-B002-110-10-B180 |
| Code number | 084Z7032 |
| Sensor element | 1 x NiCr-Ni thermocouple, Type K |
| Tolerance | Class 2 per EN 60584-2 |
| Insertion length | 110 mm insertion |
| Process connection | G 3/4 male (ISO 228-1-A) |
| Protection tube | AISI 316 Ti stainless steel, 14-24 mm diameter |
| Temperature range | -50 to +800 C (-58 to +1472 F) |
| Output signal | 4-20 mA (supply 8-35 V DC) |
| Electrical connection | Type B connection head, Pg 16 |
| Enclosure rating | IP65 per IEC 60529 |
| Packing quantity | 6 pc |
| Net weight | 0.715 kg |
| Approvals | CE |
| EAN | 5702423183425 |
| Product group | Sensors |
| Ambient temperature max. [°C] | 85 °C |
| Ambient temperature max. [°F] | 185 °F |
| Approval | CE |
| CE mark | Yes |
| China RoHS compliance | Out of scope |
| Connection material | AISI 316 Ti |
| Connection standard | ISO 228 |
| Connection type | G |
| EEE category | 5 small equipment (any external dimension < 50 cm) |
| Electrical connection size | Pg 16 |
| Enclosure rating IP | IP65 |
| EU RoHS compliance | Yes with exemptions |
| EU RoHS exemption clause | 6(c) |
| Extension length [in] | 3.94 in |
| Extension length [mm] | 100 mm |
| In scope of WEEE | Yes |
| Insertion length [in] | 4.33 in |
| Insertion length [mm] | 110 mm |
| Insertion type | Fixed |
| Number of terminals [pcs] | 2 pc |
| Output signal [mA] [max] | 20 mA |
| Output signal [mA] [min] | 4 mA |
| Process connection Male/Female | Male |
| Process connection material | AISI 316 Ti |
| Process connection size | 3/4 |
| Process connection standard | ISO 228-1-A |
| Process connection type | G |
| Protection tube diameter [in] [max] | 0.945 in |
| Protection tube diameter [in] [min] | 0.551 in |
| Protection tube diameter [mm] [max] | 24 mm |
| Protection tube diameter [mm] [min] | 14 mm |
| Protection tube material | AISI 316 TI |
| REACH Candidate List substances | Lead (CAS no. 7439-92-1) |
| Sensor element standard | EN 60584-2 |
| Sensor element tolerance | Class 2 |
| Sensor Insert | Exchangeable |
| Supply voltage [V] DC [max] | 35 V |
| Supply voltage [V] DC [min] | 8 V |
| Temperature range [°C] [max] | 800 °C |
| Temperature range [°C] [min] | -50 °C |
| Temperature range [°F] [max] | 1472 °F |
| Temperature range [°F] [min] | -58 °F |
| Thermocouple | 1 X NiCr-Ni, Type K |
| Thermocouple design std. | EN 61515 |
| Thermocouple tolerance | EN 60584-2 Class 2 |
| Transmitter setting range [°C] [max] | 800 °C |
| Transmitter setting range [°C] [min] | 0 °C |
| Transmitter setting range [°F] [max] | 1472 °F |
| Transmitter setting range [°F] [min] | 32 °F |
| Transmitter type | Galv. isolated, high lid |
| Wires [pcs] | 2 pc |
| Material | AISI 316 Ti stainless steel |
| Temperature range | -50 to +800 C (-58 to +1472 F) |
| IP rating | IP65 |
| Standard size | 110 mm insertion |
| Thread standard | ISO 228-1-A |
| MOQ | 1 |
MBT 5113 temperature transmitter. Confirm the measuring span, output (4-20 mA (supply 8-35 V DC)) and supply voltage suit the input; verify insertion length (110 mm insertion) and process thread (G 3/4) against the pocket/controller. The measuring insert is field-replaceable.