Danfoss KPR5 pressure switch, code 060-117466. Regulating range 6 to 18 bar with a narrow differential of 1 to 2.5 bar, automatic reset, SPDT contact. 1/4 in flare (male) pressure connection, IP30 enclosure, max working pressure 20 bar. Close-differential KPR member of the KP family for condensing-pressure / capacity regulation. Bellows pressure element. CE / LVD marked.
| Type | KPR5 pressure switch |
| Code number | 060-117466 |
| Regulating range | 6 to 18 bar |
| Differential range | 1 to 2.5 bar |
| Reset | automatic |
| Contact system | SPDT |
| Connection | 1/4 in flare, male |
| Max working pressure | 20 bar |
| Enclosure | IP30 |
| Approvals | CE, LVD |
| EAN | 5702428011839 |
| Product group | Switches and thermostats |
| Max. test pressure | 319.0 psig |
| Max. test pressure Pe | 22.0 bar |
| Ambient temperature range | -40 °C to 65 °C |
| Refrigerants | R113; R1233zd(E); R124; R134a; R22; R404A; R407A; R407C; R407F; R407H; R422B; R422D; R438A; R448A; R449A; R449B; R450A; R452A; R507A; R513A |
| Lubricants compatibility | Oilfree applications |
| UL approved refrigerants | R113; R124; R134a; R22; R404A; R407A; R407C; R407F; R407H; R422B; R422D; R438A; R448A; R449A; R449B; R450A; R452A; R507A; R513A |
| CE mark | Yes |
| REACH candidate-list substances | Lead (CAS no. 7439-92-1); Cadmium oxide (CAS no.1306-19-0) |
| Net weight | 0.297 kg |
| Amb | |
| Temp | |
| Note | 80 °C/176 °F for max 120 min |
| Contact function | SPDT |
| Contact rating | AC15=4 A, 440 V; AC1=10 A, 440 V; AC3=6 A, 440 V; DC13=12 W, 220 V; LR=36 A, 240 V; LR=48 A, 120 V |
| Differential | 1.00 bar to 2.50 bar |
| Electrical connection | Rubber cable gland |
| Electrical connection size | 6-14 mm |
| EN 60947 electrical properties | Insulation: 400V; Pollution degree: 3; Rated impulse voltage: 4 kV; Short circuit prot, fuse: 16A |
| EN 60947 wiring properties | Flex, ferrules: 0.5-1.5 mm2; Flex, no ferrules: 0.7-2.5 mm2; Solid/stranded: 0.75-2.5 mm2 |
| Enclosure rating IP | IP30 |
| Enclosure rating Nema (~) | 1 |
| Identical product | 060-514266 |
| Oil free refrigerants | R134a; R513A; R515B |
| Pressure connection size | 1/4 |
| Pressure connection standard | DIN 8906 |
| Pressure connection type | Flare |
| Pressure Male/Female | Male |
| Pressure sensing element | Bellows |
| Regulation range Pe | 6.00 bar to 18.00 bar |
| Reset function | Auto |
| Material | Steel/zinc-plated housing; bellows pressure element |
| Pressure rating | max working pressure 20 bar |
| Temperature range | -40 to +65 °C |
| IP rating | IP30 |
| Thread standard | 1/4 in flare, male |
| MOQ | 1 |
Condensing-pressure / capacity regulation requiring a close on-off differential; automatic reset. KPR close-differential variant of KP5.