Danfoss ICF 20-6-5MA Flexline valve station (code 027L3037). The ICF valve station combines several refrigeration control functions in one steel housing — for this configuration: Stop valve (ICFS 20), Filter (ICFF 20), Solenoid valve (ICFE 20), Manual opening (ICFO 20), Motor valve (ICM 20-A), Stop valve (ICFS 20). Connection size 20 mm, connection standard ASME B 36.10M SCHEDULE 80 (butt weld). Maximum working pressure 65 bar (943 psig); media temperature range -60 to +120 C. The ICF Flexline modular concept replaces a string of individually-mounted valves with a single station, reducing weld joints and leak paths. For low- and high-pressure refrigerants in pumped liquid, liquid injection, liquid drain and hot-gas lines, including R717 (ammonia) and R744 (CO2).
| Type | ICF 20-6-5MA Flexline valve station |
| Code number | 027L3037 |
| Connection size | 20 mm |
| Connection standard | ASME B 36.10M SCHEDULE 80 |
| Connection type | Butt weld |
| Module configuration | Stop valve (ICFS 20), Filter (ICFF 20), Solenoid valve (ICFE 20), Manual opening (ICFO 20), Motor valve (ICM 20-A), Stop valve (ICFS 20) |
| Body material | Steel |
| Surface coating | Zn (TLP) |
| Maximum working pressure | 65 bar (943 psig) |
| Media temperature range | -60 to +120 C (-76 to +248 F) |
| Weight | net weight 9.623 kg, gross weight 11.14 kg |
| Approvals | CE, EAC, TÜV, UL |
| EAN | 5702428184588 |
| Net weight | 9.623 Kilogram |
| Product group | Multifunction valves |
| Approval | CE |
| CE mark | Yes |
| China RoHS compliance | Yes with exemptions |
| China RoHS exemption clause | 7.1 |
| Connection material | Steel |
| Connection size [in] | 3/4 in |
| Connection size [mm] | 20 mm |
| Direction | Straightway |
| Equipment | Cap |
| EU RoHS compliance | Yes with exemptions |
| EU RoHS exemption clause | 6(a) |
| Flow direction indicator | Embossed 1-way arrow |
| Fluid Group | 1 |
| Max. Working Pressure [bar] | 65 bar |
| Max. Working Pressure [psig] | 943 psig |
| Module 1 | Stop valve |
| Module 1 type | ICFS 20 |
| Module 2 | Filter |
| Module 2 type | ICFF 20 |
| Module 3 | Solenoid valve |
| Module 3 type | ICFE 20 |
| Module 4 | Manual opening |
| Module 4 type | ICFO 20 |
| Module 5 | Motor valve |
| Module 5 type | ICM 20-A |
| Module 6 | Stop valve |
| Module 6 type | ICFS 20 |
| PED category | II |
| REACH Candidate List substances | Lead (CAS no. 7439-92-1) |
| Refrigerants | R134a |
| Side port connection size [in] | 3/8 in |
| Side port connection type | G |
| Side port placement | P2-P4-P5-P7-P9-P10 |
| Side port quantity [pc] | 6 pc |
| Temperature range [°C] [max] | 120 °C |
| Temperature range [°C] [min] | -60 °C |
| Temperature range [°F] [max] | 248 °F |
| Temperature range [°F] [min] | -76 °F |
| Type code ICF | ICF-20-6-20ASXFXEXOXMASX65XX |
| UL approval file name | REFRIGERANT VALVE 53R0 |
| UL mark | Yes |
| Material | Steel |
| Pressure rating | 65 bar |
| Temperature range | -60 to +120 C |
| Primary standard | ASME B 36.10M SCHEDULE 80 |
| Standard size | 20 mm |
| MOQ | 1 |
ICF Flexline modular valve station for industrial refrigeration. This code is the factory build ICF 20-6-5MA (Stop valve (ICFS 20), Filter (ICFF 20), Solenoid valve (ICFE 20), Manual opening (ICFO 20), Motor valve (ICM 20-A), Stop valve (ICFS 20)). The station bolts into a 20 mm line to ASME B 36.10M SCHEDULE 80 (butt weld); individual function modules can be serviced without removing the housing from the line. Confirm line size, connection standard, refrigerant and required functions match this configuration before ordering.