cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Danfoss GD Basic gas detection unit, ammonia (R717) electrochemical, 0–100 ppm, buzzer/light, wall-mount (148H6000)

Danfoss · Hazardous Area Equipment · Fixed Gas Detection · Denmark · danfoss.com
Part Number
148H6000  ·  HS 9027.10
Danfoss GD Basic gas detection unit, ammonia (R717) electrochemical, 0–100 ppm, buzzer/light, wall-mount (148H6000)

Danfoss GD Basic fixed gas detection unit, code 148H6000, a factory-calibrated wall-mount detector for ammonia (R717) in refrigeration machinery rooms, cold stores and process plant. Electrochemical sensing element with a 0–100 ppm measuring range and two-level alarm relays (pre-alarm 25 ppm, main alarm 35 ppm). On-board buzzer and light for local annunciation. Supplied as a complete unit with mounting kit, cable gland and a factory calibration certificate. Supply 19–29 V AC/DC. Integrates with Danfoss AK-SM system managers and standard alarm panels. HS 9027.10. OEM P/N 148H6000.

Technical Specifications

TypeGas detection unit — GD Basic
Code number148H6000
Detected gasammonia (R717)
Sensor technologyelectrochemical
Measuring range0–100 ppm
Pre-alarm (low) set point25 ppm
Main alarm (high) set point35 ppm
Local annunciationbuzzer and light
Supply voltage19–29 V AC/DC
Operating temperature-40 to +50 °C
Enclosurewall-mount, includes mounting kit and cable gland
Supplied withfactory calibration certificate
ApprovalsEU RoHS; China RoHS
EAN5714279919479
Net weight0.267 Kilogram
Product groupSensors
Alarmlimits high [ppm] sensor135 ppm
Alarmlimits low [ppm] sensor125 ppm
China RoHS complianceYes
Division40
EU RoHS complianceYes
Frequency [Hz]50/60 Hz
Gas detecting sensor versionBasic
Parts includedCable gland
PFAS content [Yes/No]No
Power consumption [A]0.25 A
REACH Candidate List substancesNo
Refrig. range [ppm] sensor1 [max]100 ppm
Refrig. range [ppm] sensor1 [min]0 ppm
RefrigerantsR717
Relative humidity (RH) [%] [max]90 %
Relative humidity (RH) [%] [min]15 %
Response delay [s]0 s
Sensor 1 typeElectrochemical
Supply voltage [V] AC [max]29 V
Supply voltage [V] AC [min]19 V
Supply voltage [V] DC [max]29 V
Supply voltage [V] DC [min]19 V
Temperature range [°C] [max]50 °C
Temperature range [°C] [min]-40 °C
Temperature range [°F] [max]122 °F
Temperature range [°F] [min]-40 °F

Properties

Temperature range-40 to +50 °C
MOQ1

Compatibility

Confirm the target gas (ammonia (R717)), detection range (0–100 ppm) and supply voltage (19–29 V AC/DC) match the installation before ordering; sensor element is gas-specific and factory-calibrated. Alarm set points 25/35 ppm are the Danfoss defaults; display-equipped GD versions allow the thresholds to be reconfigured.

Standards

Approvals

Attached Documents