Danfoss AVQ flow controller, PN 25, DN 40, flow range 0.8–12 m³/h, Kvs 16 m³/h, G 2 A external thread (003H6728)

Danfoss · HVAC & Refrigeration · Balancing Valves · Denmark · danfoss.com
Part Number
003H6728  ·  HS 8481.80
Danfoss AVQ flow controller, PN 25, DN 40, flow range 0.8–12 m³/h, Kvs 16 m³/h, G 2 A external thread (003H6728)

Danfoss AVQ (003H6728) — self-acting flow controller, PN 25, DN 40, for district heating and cooling systems. The AVQ is a self-acting flow controller for district heating and cooling systems. It holds the flow rate constant and closes when the set maximum flow is exceeded. It has a control valve with an adjustable flow restrictor and an actuator with one control diaphragm; the valve and actuator are delivered assembled with the impulse tube fitted. Flow range 0.8–12 m³/h; flow-restrictor differential pressure 0.2 bar; Kvs 16 m³/h. Maximum differential-pressure range 16 bar; media temperature 2–150 °C; cavitation factor z ≥ 0.6; seat leakage 0.05 % Kvs (IEC 60534). Valve body Ductile iron EN-GJS-400-18-LT (GGG 40.3); valve cone Dezincing free brass CuZn36Pb2As; seat Stainless steel, mat. No. 1.4571; control diaphragm EPDM. Connection External thread G 2 A (ISO 228/1), via tailpieces. Mounting version Free. Permissible media: District heating/cooling circulation water (Glycolic water up to 30%), pH 7–10. OEM P/N 003H6728. EAN 5702421542491. Technical data quoted verbatim from store.danfoss.com (code 003H6728) and the Danfoss AVQ data sheet.

Technical Specifications

Code number003H6728
TypeAVQ
Product groupPressure and flow controllers
FunctionSelf-acting flow controller (closes when set max. flow is exceeded)
Valve sizeDN 40
Pressure classPN 25
ConnectionExternal thread G 2 A (ISO 228/1), via tailpieces
Kvs value16 m³/h
Flow rate range0.8 - 12 m³/h
Flow restrictor differential pressure (Δpb)0.2 bar
Max. differential pressure range16 bar
Media temperature2 - 150 °C
Media pH7 - 10
Cavitation factor z≥ 0.6
Seat leakage rate0.05 % Kvs (IEC 60534)
Mounting versionFree
Stem positionNormally open
Permissible mediaDistrict heating/cooling circulation water (Glycolic water up to 30%)
Valve body materialDuctile iron EN-GJS-400-18-LT (GGG 40.3)
Valve cone materialDezincing free brass CuZn36Pb2As
Valve seat materialStainless steel, mat. No. 1.4571
Actuator diaphragmEPDM
EU RoHS complianceYes with exemptions (6(c))
REACH Candidate List substanceLead (CAS no. 7439-92-1)
China RoHSOut of scope
Net weight5.362 kg
Gross weight5.362 kg
EAN5702421542491

Properties

MaterialValve body Ductile iron EN-GJS-400-18-LT (GGG 40.3); valve cone Dezincing free brass CuZn36Pb2As; valve seat Stainless steel, mat. No. 1.4571; control diaphragm EPDM
Pressure ratingPN 25 (max. differential-pressure range 16 bar)
Temperature range2 to 150 °C (district heating/cooling water)
MOQ1

Compatibility

Danfoss AVQ for DN 40 district-heating/cooling flow control at PN 25. Set the maximum flow within 0.8–12 m³/h using the adjustable flow restrictor (Kvs 16 m³/h). Confirm the connection (External thread G 2 A (ISO 228/1), via tailpieces) and pressure class (PN 25) match the pipework; order the matching tailpiece/union-nut set separately. Maximum differential-pressure range 16 bar, media temperature up to 150 °C.