Danfoss AVPQ differential pressure & flow controller, PN 25, DN 15, kVS 0.4 m³/h, Δp 0.3 – 2.0 bar adjustable, flow 0.01 – 0.18 m³/h, external thread G ¾ A, return mounting (003H6920)

Danfoss · HVAC & Refrigeration · Balancing Valves · Denmark · danfoss.com
Part Number
003H6920  ·  HS 8481.80
Danfoss AVPQ differential pressure & flow controller, PN 25, DN 15, kVS 0.4 m³/h, Δp 0.3 – 2.0 bar adjustable, flow 0.01 – 0.18 m³/h, external thread G ¾ A, return mounting (003H6920)

Danfoss AVPQ (003H6920) — self-acting differential pressure and flow controller, PN 25, DN 15, for district heating and central heating systems. The AVPQ combines a control valve with an adjustable flow restrictor and an actuator with two control diaphragms; it closes on rising differential pressure or when the set maximum flow is exceeded, holding both a stable differential pressure across the controlled circuit and a limited maximum flow so connected control valves keep their authority. This AVPQ variant is mounted in the return pipe. Differential-pressure setting 0.3 – 2.0 bar adjustable via handle; kVS 0.4 m³/h; flow rate 0.01 – 0.18 m³/h. Maximum differential-pressure range 20 bar, media temperature 2–150 °C, cavitation factor z ≥ 0.6, leakage 0.02 % kVs. Valve body red bronze CuSn5ZnPb (Rg5), valve cone dezincing-free brass CuZn36Pb2As, seat stainless steel 1.4571, control diaphragms EPDM. Connection external thread G ¾ A (ISO 228/1) via tailpieces (ordered separately); supplied complete with compression fittings for Ø6 mm copper impulse tube. Media: district heating/cooling circulation water; glycolic water up to 30%. OEM P/N 003H6920. Technical data quoted verbatim from the Danfoss AVPQ/AVPQ-F data sheet and store.danfoss.com (code 003H6920). differential-pressure range 20 bar); Temperature range: 2 – 150 °C (heating/cooling water); glycolic water up to 30%; HS code: 8481.80. Used in commercial refrigeration, provision-room cooling and reefer plant rooms across HFC, HFO and CO2 (R744) refrigerants.

Technical Specifications

Code number003H6920
TypeAVPQ
Product groupPressure flow controllers
FunctionDifferential pressure and flow controller (self-acting)
DescriptionSelf-acting differential pressure control and flow limiter (district heating), adjustable setting, return-pipe mounting
Valve sizeDN 15
Pressure classPN 25
ConnectionExternal thread G ¾ A (ISO 228/1), via tailpieces
kVS value0.4 m³/h
Flow rate [m³/h]0.01 – 0.18
Differential pressure setting0.3 – 2.0 bar (adjustable, factory range)
Flow-restrictor differential pressure (dpb)0.2 bar
Max. differential pressure range20 bar
Media temperature2 – 150 °C
Cavitation factor z≥ 0.6
Leakage rate0.02 % kVs
Stem positionNormally open
Mounting versionReturn (installed in the return pipe)
Permissible mediaDistrict heating/cooling circulation water; glycolic water (≤30%)
Valve body materialRed bronze CuSn5ZnPb (Rg5)
Valve cone materialDezincing-free brass CuZn36Pb2As
Valve seat materialStainless steel, mat. no. 1.4571
Control diaphragmEPDM
EU RoHS complianceOut of scope
China RoHS complianceOut of scope
Net weight3.525 kg
Gross weight3.525 kg
EAN5702421545126
HS code8481.80

Properties

MaterialValve body red bronze CuSn5ZnPb (Rg5); valve cone dezincing-free brass CuZn36Pb2As; seat stainless steel 1.4571; control diaphragms EPDM
Pressure ratingPN 25 (max. differential-pressure range 20 bar)
Temperature range2 – 150 °C (heating/cooling water); glycolic water up to 30%
MOQ1

Compatibility

Danfoss AVPQ for DN 15 district-heating or central-heating circuits where BOTH differential pressure and maximum flow must be held, installed in the return pipe. Size by the branch design flow (0.01 – 0.18 m³/h here, kVS 0.4) and set the differential-pressure setpoint within 0.3 – 2.0 bar. Confirm the connection (external thread G ¾ A, ISO 228/1) and pressure class (PN 25) match the pipework; order the matching tailpiece/union-nut set separately (impulse-tube compression fittings are included). For mounting in the opposite pipe use the flow-mounted AVPQ-4; for differential-pressure control without flow limitation use the AVP; for flow limitation without integrated Δp handle use the AVPB. Maximum differential-pressure range 20 bar, media temperature 2–150 °C.