Danfoss AB-QM ANSI ½" — high-flow pressure-independent balancing and control valve (PICV) with external NPT thread for North-American terminal-unit piping. A built-in differential-pressure controller keeps the flow through the settable orifice constant regardless of pressure fluctuations elsewhere in the network, so each terminal delivers its design flow without manual re-balancing; the presetting dial fixes the maximum flow and the valve also acts as a shut-off. CW 617N body, External thread NPT connection, maximum flow 5 gal/min, control differential pressure 5 psi to 60 psi, static pressure to 300 psi, media temperature 15 °F to 250 °F. Supplied without test plugs. Actuator connection M30 x 1.5. OEM P/N 003Z1332. EAN 5710104061535. Technical data quoted verbatim from store.danfoss.com (code 003Z1332).
| Code number | 003Z1332 |
| Type | AB-QM ANSI |
| Product group | Pressure independent balancing and control valves |
| Description | AB-QM ½", High flow, without test plugs, pressure independent balancing and control valve |
| Valve size | ½" High flow |
| Valve body material | CW 617N |
| Connection types | External thread NPT |
| Actuator connection | M30 x 1.5 |
| Test plugs | Without test plugs |
| Flow nominal [m³/h] | 0 m³/h |
| Flow [gpm] [Max] | 5 gal/min |
| Stroke [mm] | 4 mm |
| Static pressure [psi] [Max] | 300 psi |
| Differential pressure range [psi] [Min] | 5 psi |
| Differential pressure range [psi] [Max] | 60 psi |
| Media temperature [°F] [Min] | 15 °F |
| Media temperature [°F] [Max] | 250 °F |
| Contains batteries | No |
| EU RoHS compliance | Yes with exemptions |
| EU RoHS exemption clause | 6(c) |
| China RoHS compliance | Out of scope |
| REACH Candidate List substances | Lead (CAS no. 7439-92-1) |
| SCIP dossier no. | 4308eb33-f8bb-4ce9-85ed-0fa526a763b3 |
| SCIP dossier product name | AB-QM 1/2" LF without test plugs |
| Net weight | 0.47 Kilogram |
| Gross weight | 0.49 Kilogram |
| Volume | 1.339 Liter |
| EAN | 5710104061535 |
| Material | Valve body CW 617N |
| Pressure rating | Static pressure 300 psi |
| Temperature range | 15 °F to 250 °F (media) |
| MOQ | 1 |
AB-QM ANSI is the NPT-threaded PICV for North-American installations — one per terminal unit. Select by pipe size (½") and required design flow (max 5 gal/min); the high-flow body sets the flow band and the presetting dial fixes the actual maximum. Fit a compatible M30 x 1.5 actuator for modulating or on/off control. Order the with-test-plugs variant if commissioning flow measurement is required.