cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-08
sales@cballast.com
cballast.com

Danfoss MBS 3350 Pressure Transmitter 0–40 bar 4–20 mA

Danfoss · Sensors & Instrumentation · Pressure Transmitters · Denmark · danfoss.com
Part Number
060G6615  ·  HS 9026.20
Danfoss MBS 3350 Pressure Transmitter 0–40 bar 4–20 mA

Danfoss MBS 3350 pressure transmitter, genuine OEM code 060G6615. Output 4–20 mA (2-wire) over a measuring range of 0–40 bar (0–580 psi), supply voltage 9–32 V DC. Pressure reference sealed gauge. Pressure connection Flange, port Ø2.5; electrical connection Angular connector, M20 (EN 175301-803-A). Wetted parts AISI 316L stainless steel; enclosure IP65. Spec key MBS 3350-2611-H3CD28-3. Approvals: cULus UL Recognized, CE. EAN 5702428996822.

Technical Specifications

BrandDanfoss
Part number060G6615
TypeMBS 3350 pressure transmitter
CategorySensors & Instrumentation — Pressure Transmitters
Measuring range0–40 bar (0–580 psi)
Referencesealed gauge
Output signal4–20 mA (2-wire)
Supply voltage9–32 V DC
Accuracy≤ ±0.5 % FS typical, ≤ ±1.0 % FS maximum
Pressure connectionFlange, port Ø2.5
Electrical connectionAngular connector, M20 (EN 175301-803-A)
Wetted partsAISI 316L stainless steel
Media/ambient temperature-40°C to +85°C (medium/ambient)
Enclosure ratingIP65
Spec keyMBS 3350-2611-H3CD28-3
EAN5702428996822
ApprovalscULus UL Recognized, CE
HS code9026.20
Net weight0.346 Kilogram
Product groupSensors
+ supplyPin 1
- supplyPin 2
Accuracy, max. [±FS%]1 %
Accuracy, typical [±FS%]0.5 %
Ambient temperature range [°C] [max]100 °C
Ambient temperature range [°C] [min]-40 °C
Ambient temperature range [°F] [max]212 °F
Ambient temperature range [°F] [min]-40 °F
ApprovalC UL US UL Recognized
CE markYes
China RoHS complianceOut of scope
Compensated temp. range [°C] [max]100 °C
Compensated temp. range [°C] [min]0 °C
Compensated temp. range [°F] [max]212 °F
Compensated temp. range [°F] [min]32 °F
EEE category5 small equipment (any external dimension < 50 cm)
Electrical conn
Male/FemaleMale and Female
Electrical connection sizeM20
Electrical connection standardEN 175301-803-A
Enclosure rating IPIP65
EU RoHS complianceYes with exemptions
EU RoHS exemption clause6(c)
Flush diaphragmNo
High Clipping Level22.4
In scope of WEEEYes
International Article Number5702428996822
Intrinsically safeNo
Low Clipping level3.6
Medium temperature range [°C] [max]125 °C
Medium temperature range [°C] [min]-20 °C
Medium temperature range [°F] [max]257 °F
Medium temperature range [°F] [min]-4 °F
Non-linearity BFSL [±FS%]0.2 %
Output signal [mA] [max]20 mA
Output signal [mA] [min]4 mA
Overload pressure max. [bar]240 bar
Overload pressure max. [psi]3481 psi
Pressure connection sizePort Ø2.5
Pressure connection standardN/A
Pressure connection typeFlange
Pressure Male/FemaleFemale
Pressure range [bar] [max]40 bar
Pressure range [bar] [min]0 bar
Pressure range [psi] [max]580 psi
Pressure range [psi] [min]0 psi
Pressure referenceSealed gauge
Pulse-snubberYes
REACH Candidate List substancesLead (CAS no. 7439-92-1)
Response time max. [ms]4 ms
Specification keyMBS 3350-2611-H3CD28-3
Supply voltage [V] DC [max]32 V
Supply voltage [V] DC [min]9 V
UL markYes

Properties

MaterialAISI 316L stainless steel
Pressure rating0–40 bar (0–580 psi)
Temperature range-40°C to +85°C (medium/ambient)
IP ratingIP65
Standard sizeFlange, port Ø2.5
Thread standardFlange, port Ø2.5
MOQ1

Compatibility

MBS 3350 transmitter; sealed gauge reference, 4–20 mA (2-wire). Flange, port Ø2.5 process port with Angular connector, M20 (EN 175301-803-A).

Attached Documents