Twin-tube Coriolis mass flow and density meter for hydrocarbons, chemicals, bunker fuel.
| Nominal size | DN25 (1") |
| Max flow (water) | 7.5 t/h |
| Accuracy | ±0.10 % of rate (liquid mass) |
| Density accuracy | ±0.5 kg/m³ |
| Process connection | EN 1092-1 PN40 / ASME B16.5 Class 300 flanged |
| Wetted material | 316L stainless (1.4404) |
| Temperature | -50 to +200 °C |
| Pressure | PN40 / Class 300 |
| Output | 4-20 mA + HART, Modbus RTU, pulse / frequency |
| Ingress protection | IP67 / NEMA 4X |
| Hazardous area | Ex d IIB T4 or Ex ia IIC T4 variants available |
| Marking | Coriolis tag plate, calibration certificate ISO/IEC 17025 traceable |
| Material | 316L stainless steel |
| MOQ | 1 ea |
Form-fit envelope of Endress+Hauser Promass F / Promass Q / Promass 80F, Emerson Micro Motion CMF, KROHNE OPTIMASS 6400/7400 and Yokogawa ROTAMASS DN25 Coriolis meters. Aftermarket Coriolis meters with matching tube geometry can be drop-installed on the same flange face and signal-wired into existing HART loops without skid rework.