Coriolis Mass Flow Meter DN100 (4") — 316L Wetted, 4-20 mA + HART

Generic · Instrumentation · Flow Meters
Part Number
CFM-CORI-DN100-316L-HART  ·  HS 9026.10
Coriolis Mass Flow Meter DN100 (4") — 316L Wetted, 4-20 mA + HART

Twin-tube Coriolis mass flow and density meter for hydrocarbons, chemicals, bunker fuel.

Technical Specifications

Nominal sizeDN100 (4")
Max flow (water)330 t/h
Accuracy±0.10 % of rate (liquid mass)
Density accuracy±0.5 kg/m³
Process connectionEN 1092-1 PN40 / ASME B16.5 Class 300 flanged
Wetted material316L stainless (1.4404)
Temperature-50 to +200 °C
PressurePN40 / Class 300
Output4-20 mA + HART, Modbus RTU, pulse / frequency
Ingress protectionIP67 / NEMA 4X
Hazardous areaEx d IIB T4 or Ex ia IIC T4 variants available
MarkingCoriolis tag plate, calibration certificate ISO/IEC 17025 traceable

Properties

Material316L stainless steel
MOQ1 ea

Compatibility

Form-fit envelope of Endress+Hauser Promass F / Promass Q / Promass 80F, Emerson Micro Motion CMF, KROHNE OPTIMASS 6400/7400 and Yokogawa ROTAMASS DN100 Coriolis meters. Aftermarket Coriolis meters with matching tube geometry can be drop-installed on the same flange face and signal-wired into existing HART loops without skid rework.

Standards

Approvals