| Principle | magnetic-inductive (Faraday) |
| Size | DN 6 to DN 100 |
| Accuracy | ±0.4 % of measured value |
| Liquid conductivity | ≥ 20 µS/cm |
| Output | 4-20 mA + pulse |
| Process | wafer or flanged |
| Temperature | -10 to +90 °C |
| Pressure | up to 16 bar |
| Type SE56 | |
| Sensor housing | Carbon steel painted (stainless steel 304 or 316 on request) Electrode: Stainless steel 316L (Alloy C, Titanium, Tantalum |
| Platinum-rhodium on request) Lining | PP or ebonite (hard rubber) (PTFE on request) Seal: FKM (EPDM on request) with PP lining • Without gasket with ebonite (hard rubber) lining (with PTFE lining on request) Pipe diameter: DN 25...DN 200 (upper DN on request) Under reference conditions: water temperature = 20 °C, ambient temperature = 25 °C, constant flow rate during the test, liquid Measurement deviation: If used with SE56 transmitter • In standard compact version: ± 0.2 % of reading • In standard remote version: ± 0.2 % of reading • In Basic compact version: ± 0.8 % of reading.. |
| Repeatability | If used with SE56 transmitter • In standard compact version: ± 0.1 % • In standard remote version: ± 0.1 % • In Basic compact version: ± 0.2 % • In compact version without.. |
| Vacuum resistance | 200 mbar (2.9 PSI) absolute at 100 °C (212 °F) Fluid temperature: With PP lining used with SE56 transmitter: –– in standard compact version: - 0...+ 60 °C (+ 32...+ 140 °F) –– in standard remote version: - 0...+ 60 °C (+ 32...+ 140 °F) –– in.. |
| Fluid pressure | PN 16 (232 PSI) with PP lining minimum conductivity: 5 µS/cm (or 20 µS/cm with demineralised water) Process connection: Wafer Electrical connection: 2 cable glands PG9 (for remote version of the sensor) Degree of protection according: If use with SE56 transmitter: CE directives: The applied standards, which verify conformity with the EU Directives, can be found on the EU Type Examination Certificate and/or the EU Declaration of conformity (if applicable) |
| Pressure equipment directives | The device is subject to the requirements of the Pressure Equipment Directive 2014/68/EU. Category II device for group 1 and 2 fluids under the following conditions: • maximum.. |
| Ambient temperature | If used with SE56 transmitter: • in standard compact version: - 20...+ 60 °C (- 4...+ 140 °F) (operation and storage) • in standard remote version: - 20...+ 60 °C (- 4...+ 140.. |
| Relative air humidity | ≤ 90 %, without condensation Height above sea level: Max. 2000 m Operating conditions: Continuous Equipment mobility: Fixed device Application range: Indoor and outdoor (protect the device against electromagnetic interference, ultraviolet rays and against the effects of climatic conditions) Installation category: Category II according to UL/EN 61010‑1 Pollution degree: Degree 2 according to UL/EN 61010‑1 |