Triogen UV CF 170 medium-pressure ultraviolet disinfection system for commercial pools, spas and water features. Rated flow 170 m3/h (748 US gpm) at a UV dose of 60 mJ/cm2 and 255 m3/h (1122 US gpm) at 40 mJ/cm2, both at 95% UVT and end of 8,000-hour lamp life. Single 3.0 kW medium-pressure polychromatic lamp (largest single-lamp CF unit), electropolished 316L stainless reactor vessel rated 10 bar(g), Smartdrive automatic wiper with UV monitor, wall-mounted touchscreen control panel. CE marked, UL listed, NSF50 certified; manufactured to ISO 9001:2015.
| Model | CF 170 |
| Flow @60 mJ/cm2 (95% UVT, end of lamp life) | 170 m3/h (748 US gpm) |
| Flow @40 mJ/cm2 (95% UVT, end of lamp life) | 255 m3/h (1122 US gpm) |
| Lamp | 1 x medium-pressure polychromatic, 3.0 kW, 8,000 h |
| Reactor vessel | electropolished 316L stainless steel, 10 bar(g) |
| Lamp / thimble | high-purity quartz |
| Flanges | BS EN1092 PN10, ANSI 150 or COMBI (confirm DN at order) |
| Control panel | wall-mounted touchscreen microprocessor, polyester-coated mild steel, IP54 |
| Wiper | Smartdrive automatic, with UV monitor |
| Comms | data logging, BMS, Modbus, Ethernet |
| Supply | 230/1/50 or 3-phase 380-480 V (confirm at order) |
| Certification | CE marked, UL listed, NSF50 certified (options available); ISO 9001:2015 |
| Material | Electropolished 316L stainless steel reactor vessel (rated 10 bar(g)); high-purity quartz lamp and thimble; polyester-coated mild steel control panel (IP54) |
| Pressure rating | 10 bar(g) (reactor vessel) |
| IP rating | IP54 (control panel) |
| Primary standard | ISO 9001:2015 |
| Standard size | CF 170 |
| Thread standard | Flanged BS EN1092 PN10, ANSI 150 or COMBI |
| Dimensions | Maintenance area and control-panel footprint are configured per the CF table (one dimension band spans several models); confirm exact dimensions at order. |
| MOQ | 1 |
Triogen UV CF 170 is the largest single-lamp CF commercial-pool unit (3.0 kW); models above it (CF 220 and up) use twin or multi-lamp configurations. Sized to free-chlorine reduction and chloramine destruction at the pool's flow and UV-transmittance. Confirm required UV dose, design flow, UVT and flange standard before ordering; flange size and dimensions are configured options per the CF table.