Ultraviolet control panels dissipate real heat from ballasts and ignitors into a largely sealed enclosure. Cooling failures present as intermittent, temperature-dependent shutdowns rather than as a clean fault, so airflow parts are worth replacing on condition rather than on failure. This is the 212 × 200 mm cabinet filter for the InLine 1000+. Original Berson number 0.43.101.
| Component type | Cabinet air filter |
| Size | 212 × 200 mm |
| Original part number | 0.43.101 |
| Fits | Berson InLine 1000+ |
| HS code | 8421.99 |
| MOQ | 1 |
Compatible with Berson InLine UV reactor series.