The Type 8741 mass flow controller (MFC)/mass flowmeter (MFM) for gases is suitable for a variety of applications and is available with industrial Ethernet, analogue or fieldbus interfaces. The variant with CANopen-based Bürkert Systembus (büS) is suitable for integration into existing CANopen networks or - in combination with the Type ME43 fieldbus gateway - for integration into all common industry standards for Industrial Ethernet and/or fieldbus. The latter option is tailor-made for applications with many control loops. Up to 32 MFCs or MFMs can be connected to one fieldbus gateway. Type ME43 transmits the internal CANopen-based communication to Industrial Ethernet and fieldbus standards. The mass flow controller/mass flow meter Type 8741 can be switched at any time between büS and CANopen communication. Type 8741 can be configured as an MFM or an MFC according to demand. Furthermore, a Modbus RTU variant is also available. Optionally, up to four calibration curves can be stored in the device. The thermal MEMS sensor is located directly in the gas stream and therefore achieves very fast response times. As the actuator, a Bürkert direct-acting proportional valve guarantees high response sensitivity.

Technical Specifications

SealFKM or EPDM (depending on gas)
Base blockAluminium or stainless steel 1.4404/316L
Wetted partsStainless steel 1.4310/302, 1.4113/434, 1.4305/303
Total weightApprox. 500 g (aluminium base block)
LED displayRGB LED according to NAMUR NE107
Nominal flow range (QN)10 ml…160 lN/min (N2)
Operating pressureMFM: max. 25 bar
Repeatability± 0.1 % FS
Turndown ratio1:50, optionally 1:100
Settling time (MFC)/Response time< 300 ms
Valve positionNormally closed
Nominal diameter0.05…8 mm
KVS value range0.00006…1.1 m3/h
Operating voltage24 V DC
Power consumption1…3 W (as MFM)