| Operating pressure | 2–10 bar |
| Medium temperature | 0–50 °C |
| Body | PA (polyamide), aluminium (Type 0460) PA (polyamide), aluminium (Type 0461) |
| Seal | FKM, NBR and PUR NBR |
| Width per station | 11 mm 16.5 mm |
| Manual override | Standard Standard |
| Number of valve slots | For single valves: max. 64 Max. 32 For impulse and double valves: max. 32 When using Type 0461: 24 |
| Maximum number of valve functions | Max. 64 Max. 32 |
| Pneumatic intermediate supply | Necessary for single valves after 24 valve Necessary after 16 valve functions functions. Necessary after 16 valve functions for double valves |
| Pressure data | Overpressure to atmospheric pressure Overpressure to atmospheric pressure |
| Pressure range | Vac....10 bar Vac....10 bar |
| External supply air (auxiliary pilot air) | > 2.5 bar (Type 0460: not possible) > 2.5 bar (Type 0461: not possible) |
| Flow rate QNn value air | 200...300 l/min measured at + 20 °C, 6 bar 500...700 l/min measured at + 20 °C, 6 bar pressure at valve inlet and 1 bar differential pressure at valve inlet and 1 bar... |
| Nominal operating mode | Continuous operation (100 % duty cycle) Continuous operation (100 % duty cycle) |
| Switching time | Measured according to ISO 12238 Measured according to ISO 12238 |
| Operating voltage | 24 V DC 24 V DC |
| Voltage tolerance | + 20 %/- 15 % + 20 %/- 15 % (when using Type 0460: ± 10 %) (when using Type 0461: ± 10 %) |
| Residual ripple (at DC) | 1 Vss 1 Vss |
| Nominal power of each valve | For single valves: 0.8 W For impulse and 2 W, 1 W double valves: 2x 0.8 W with power reduction |
| Nominal current of each valve | 43 mA (28 mA holding current after 120 ms) 85 mA (52 mA holding current after 120 ms) 41 mA (when using Type 0460) 41 mA (when using Type 0461) |
| Digital input | Via cooperation partners Via cooperation partners |
| Protection class | III according to VDE 106, IEC 60536 III according to VDE 106, IEC 60536 |
| Operating medium | Oil-free or lubricated compressed dry air Oil-free or lubricated compressed dry air (5 μm filter recommended) (5 μm filter recommended) |
| Compressed air quality | ISO 8573 - 1: 2010 |
| Class 7.4.4 ISO 8573 - 1 | 2010, Class 7.4.4 |
| Degree of protection | IP20 IP20 IP65 in closed control cabinets IP65 in closed control cabinets |
| Working connection | D 4, D 6, D ¼, D 8, NPT ⅛, G ⅛ D 8, NPT ⅜, G ⅛ |
| Air supply connection | G ¼, NPT ¼, D 10, G ⅜, NPT ⅜ G ⅜, NPT ⅜ |
| Communication module | WAGO I/O System 750 WAGO I/O System 750 |