| Manufacturer part number (MPN) | TF96-87 |
| EAN / GTIN | 4013614483028 |
| Sales unit | pcs |
| Setting range | 75-87 A |
| Country of Origin | India |
| Product Sales Status | Active |
| Product Net Width | 69.9 mm |
| Product Net Height | 106.9 mm |
| Product Net Depth / Length | 106.3 mm |
| Rated Operational Voltage | Auxiliary Circuit 600 V AC/DC; Main Circuit 690 V AC; Main Circuit 440 V DC |
| Rated Operational Current (I e ) | 87 A |
| Rated Frequency (f) | Auxiliary Circuit 50 Hz; Auxiliary Circuit 60 Hz; Auxiliary Circuit DC; Main Circuit 50 Hz; Main Circuit 60 Hz |
| Rated Impulse Withstand Voltage (U imp ) | Auxiliary Circuit 6 kV; Main Circuit 8 kV |
| Rated Insulation Voltage (U i ) | 690 V |
| Number of Poles | 3P |
| Number of Auxiliary Contacts NC | 1 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Protected Poles | 3 |
| Conventional Free-air Thermal Current (I th ) | Auxiliary Circuit NC 6 A; Auxiliary Circuit NO 4 A |
| Rated Operational Current AC-15 (I e ) | (120 V) NC 3 A; (120 V) NO 0.5 A; (240 V) NC 3 A; (240 V) NO 0.5 A; (400 V) NC 0.75 A; (400 V) NO 0.5 A; (500 V) NC 0.75 A; (500 V) NO 0.5 A |
| Rated Operational Current DC-13 (I e ) | (125 V) NC 0.55 A; (125 V) NO 0.55 A; (24 V) NC 1.25 A; (24 V) NO 1.25 A; (250 V) NC 0.27 A; (250 V) NO 0.27 A; (500 V) NC 0.15 A; (500 V) NO 0.15 A; (60 V) NC 0.55 A; (60 V) NO 0.55 A |
| Degree of Protection | Housing IP20; Main Circuit Terminals IP10 |
| Pollution Degree | 3 |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²; Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²; Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²; Flexible 1/2x 0.75 ... 1 mm²; Flexible 1/2x 1 ... 2.5 mm²; Rigid 1/2x 0.75 ... 4 mm² |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 6 ... 35 mm²; Flexible with Ferrule 1x 6 ... 50 mm²; Flexible with Insulated Ferrule 1/2x 6 ... 16 mm²; Flexible with Insulated Ferrule 1x 6 ... 50 mm²; Flexible 1/2x 6 ... 35 mm²; Flexible 1x 6 ... 50 mm²; Rigid 1/2x 6 ... 35 mm²; Rigid 1x 6 ... 50 mm² |
| Tightening Torque | Auxiliary Circuit 1 ... 1.2 N·m; Main Circuit 6.0 ... 9.0 N·m |
| Wire Stripping Length | Auxiliary Circuit 9 mm; Main Circuit 20 mm |
| Recommended Screw Driver | Auxiliary Circuit Pozidriv 2; Main Circuit Hexagon 4 |
| Mounting Position | 1 ... 6 |
| Power Loss | at Rated Operating Conditions per Pole 2.9 ... 3.9 W |
| Suitable For | AF80; AF96 |
| Standards | IEC/EN 60947-1; IEC/EN 60947-4-1; IEC/EN 60947-5-1; UL 60947-1; UL 60947-4-1; IEC 60335-2-40 A2L |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC |
| Contact Rating UL/CSA | (NC:) B600; (NC:) Q600; (NO:) Q600; (NO:) D300 |
| Connecting Capacity Main Circuit UL/CSA | Flexible 1x 8-1 AWG; Flexible 2x 8-3 AWG; Stranded 1x 8-1 AWG; Stranded 2x 8-3 AWG |
| Connecting Capacity Auxiliary Circuit UL/CSA | Flexible 1/2x 18-12 AWG; Stranded 1/2x 18-12 AWG |
| Tightening Torque UL/CSA | Auxiliary Circuit 9 ... 11 in·lb; Main Circuit 53 ... 80 in·lb |
| Ambient Air Temperature | Operation -40 ... +70 °C; Operation Compensated -40 ... +70 °C; Storage -50 ... +80 °C |
| Ambient Air Temperature Compensation | Yes |
| Maximum Operating Altitude Permissible | 2000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | 11 ms Pulse 25g |
| Resistance to Vibrations | 5g 3 ... 150 Hz |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| EcoSolutions Profile | 1SFC100125C0355 |
| End Of Life Disassembling Instructions | 1SAC200334H0001 |
| Environmental Information | 1SAC200059H0009 |
| Environmental Product Declaration - EPD | 1SAC200249H0001 |
| Improved Energy Efficiency for Customers | Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 93.3 % |
| A2L Certificate – IEC | 1SAA941000-4601 |
| ABS Certificate | 1SAA941003-0101 |
| ATEX Certificate | 1SAA941006-3901 |
| BV Certificate | 1SAA941001-0203 |
| CB Certificate | 1SAA941015-2001 |
| CCC Certificate | 2024010304636179 |
| CQC Certificate | CQC2014010309689434 |
| Declaration of Conformity - CCC | 2020980309000292 |
| Declaration of Conformity - CE | 1SAD101100-3503 |
| Declaration of Conformity - UKCA | 1SAD201100-3503 |
| DNV GL Certificate | 1SAA941004-0301 |
| EAC Certificate | 1SAA941002-2701 |
| IECEx Certificate | 1SAA941002-4001 |
| LR Certificate | 1SAA941003-0501 |
| RINA Certificate | RINA_ELE098115XG |
| RMRS Certificate | 1SAA941002-0701 |
| UL Certificate | E48139-20130329 |
| Object Classification Code | F |
| ETIM 9 | EC000106 - Thermal overload relay |
| eClass | V11.0 : 27371501 |
| UNSPSC | 39122330 |
| IDEA Granular Category Code (IGCC) | 5366 >> Thermal overload relay |
| E-Number (Finland) | 3706594 |
| E-Number (Norway) | 4116798 |
| E-Number (Sweden) | 3210274 |