JF.BL. DDA202 B APR-25/30MA (2CSB202592R1250)

ABB Automasjon · Electrical Components · RCDs & RCBOs
Part Number
2CSB202592R1250  ·  HS 8536.30
JF.BL. DDA202 B APR-25/30MA (2CSB202592R1250)

ABB 2CSB202592R1250 — The RCD block DDA200 series is suitable for assembly with MCBs S200 series and S300P. Type B is also sensitive to continuous current pulsating earth fault currents. They are used for protection in installations with electronic equipment according to EN 50178. Applications: tertiary and industrial.

Technical Specifications

Manufacturer part number (MPN)2CSB202592R1250
EAN / GTIN8012542748021
Sales unitpcs
Carbon Footprint (Full Lifecycle)21.448512 kg CO₂ eq
EcoSolutions Profile9AKK108471A0995
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 69.47 %
ABB Site Meeting Group Waste To Landfill TargetNo non-hazardous waste is sent to a landfill; UL 2799 Zero Waste To Landfill Validation available
Sustainable Material Content in Packaging (wt. %)Recycled Cardboard - 85.84 %; Recycled Paper - 0 %; Recycled Paper - 0 %
Extended Product LifetimeProduct Durability
End Of Life Disassembling Instructions9AKK108469A7485
Environmental Product Declaration - EPD9AKK108469A8934
Type of Residual CurrentType B
Test Voltage (Out)195...254 V
Rated Current Sensitivity30 mA
Maximum Surge Current3 kA
Leakage Current TypeB
Power Supply ConnectionArbitrary
Electrical Endurance10000 cycle
Number of Poles2P
Number of Modular Spacings per DIN Rail6
Operating Characteristic10ms Delay (High Immunity)
Tightening Torque2.8 N·m
Cable Cross-SectionFlexible Cable 0...25 mm²; Rigid Cable 0...25 mm²
Connecting CapacityFlexible 0...25 mm²; Rigid Cable 0...25 mm²
Short-Circuit Current Rating (SCCR)1 kA
Rated Voltage (U r )230...230 V
Rated Operational Voltage230 V
Rated Insulation Voltage (U i )acc. to IEC/EN 60664-1 500 V
Rated Impulse Withstand Voltage (U imp )4 kV
Rated Current (I n )25 A
Rated Residual Current30 mA
Rated Frequency (f)50 / 60 Hz
Power LossTotal 2 W
Number of Modules6
Ambient Temperature-25...55 °C
Ambient Air TemperatureOperation -25...50 °C
Degree of ProtectionIP2X
Pollution Degree2
Resistance to Vibrations20 Cycles with Load 0.8 In: 1g or 0.1mm 5...150...5 Hz
Resistance to Shock acc. to IEC 60068-2-2725g 2 shocks 13 ms
Environmental InformationRefer to RoHS
Product Net Width105 mm
Product Net Height93 mm
Product Net Depth / Length69 mm
Declaration of Conformity - CE9AKK106713A5615
Instructions and Manuals9AKK108467A7092
ETIM 9EC002297 - Residual current circuit breaker (RCCB) module
UNSPSC39121601
eClassV11.0 : 27142210
IDEA Granular Category Code (IGCC)4875 >> Residual current circuit breaker (RCCB)
Object Classification CodeF
StandardsIEC/EN 61009 Ann. G; IEC/EN 62423
Nominal voltage230 V
Nominal current25 A
Rated fault current adjustableNo
Rated fault current0.03 A
Max. delay time10 ms
Delay adjustableNo
Surge current capacity3 kA
Frequency50/60 Hz
Rated insulation voltage Ui500 V
Rated impulse withstand voltage Uimp4 kV
Connectable conductor cross section solid-core25 mm²
Connectable conductor cross section multi-wired25 mm²
Anti-nuisance tripping versionYes
With interlocking deviceYes
Ambient temperature during operating-25–55 °C
Country of originItaly

Properties

MOQ1

Cross-References

Attached Documents