Residual Current Block DDA203A 63A/300MA (2CSB203701R3630)

ABB Automasjon · Electrical Components · RCDs & RCBOs
Part Number
2CSB203701R3630  ·  HS 8536.30
Residual Current Block DDA203A 63A/300MA (2CSB203701R3630)

ABB 2CSB203701R3630 — The RCD block DDA200 series is suitable for assembly with MCBs S200 series and S300P. It assures protection against the effects of sinusoidal alternating and direct pulsating earth fault currents, protection, against indirect contacts and additional protection against direct (with sensitivity = 30 mA) contacts. It is provided with two additional contacts to be used in emergency circuits for remote opening in positive safety. Applications: commercial, industrial.

Technical Specifications

Manufacturer part number (MPN)2CSB203701R3630
EAN / GTIN8012542802204
Sales unitpcs
Rated current63 A
Carbon Footprint (Full Lifecycle)9.84723 kg CO₂ eq
EcoSolutions Profile9AKK108471A0995
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 69.47 %
ABB Site Meeting Group Waste To Landfill TargetNo non-hazardous waste is sent to a landfill; UL 2799 Zero Waste To Landfill Validation available
Sustainable Material Content in Packaging (wt. %)Recycled Cardboard - 85.84 %; Recycled Paper - 0 %; Recycled Paper - 0 %
Extended Product LifetimeProduct Durability
End Of Life Disassembling Instructions9AKK108469A7485
Environmental Product Declaration - EPD9AKK108469A8934
Type of Residual CurrentType A
ApplicationFor emergency stop
Test Voltage (Out)310...440 V
Rated Current Sensitivity300 mA
Leakage Current TypeA
Power Supply ConnectionArbitrary
Electrical Endurance10000 cycle
Number of Poles3P
Number of Modular Spacings per DIN Rail7
Operating CharacteristicInstantaneous (AE for Emergency Stop)
Tightening Torque2.8 N·m
Options ProvidedFor emergency stop
Cable Cross-SectionFlexible Cable 0...25 mm²; Rigid Cable 0...25 mm²
Connecting CapacityFlexible 0...25 mm²; Rigid Cable 0...25 mm²
Short-Circuit Current Rating (SCCR)1 kA
Rated Voltage (U r )230/400 V
Rated Operational Voltage400 V
Rated Insulation Voltage (U i )acc. to IEC/EN 60664-1 500 V
Rated Impulse Withstand Voltage (U imp )4 kV
Rated Current (I n )63 A
Rated Residual Current300 mA
Rated Frequency (f)50 / 60 Hz
Power LossTotal 7.6 W
Number of Modules7
Ambient Temperature-25...55 °C
Ambient Air TemperatureOperation -25...50 °C
Degree of ProtectionIP2X
Pollution Degree2
Resistance to Vibrations20 Cycles with Load 0.8 In: 1g or 0.1mm 5...150...5 Hz
Resistance to Shock acc. to IEC 60068-2-2725g 2 shocks 13 ms
Environmental Information2CSC427001K2701
Product Net Width122.5 mm
Product Net Height93 mm
Product Net Depth / Length69 mm
Declaration of Conformity - CE9AKK106713A5614
Instructions and Manuals9AKK106930A7504
ETIM 9EC002297 - Residual current circuit breaker (RCCB) module
UNSPSC39121601
eClassV11.0 : 27142210
IDEA Granular Category Code (IGCC)4875 >> Residual current circuit breaker (RCCB)
Object Classification CodeF
StandardsIEC/EN 61009 Ann. G
Nominal voltage230–400 V
Nominal current63 A
Rated fault current adjustableNo
Rated fault current0.3 A
Delay adjustableNo
Frequency50/60 Hz
Rated insulation voltage Ui500 V
Rated impulse withstand voltage Uimp4 kV
Connectable conductor cross section solid-core25 mm²
Connectable conductor cross section multi-wired0–25 mm²
Anti-nuisance tripping versionNo
With interlocking deviceYes
Ambient temperature during operating-25–50 °C
Country of originItaly

Properties

MOQ1

Cross-References

Attached Documents