Soft start PSE250-600-70-1 250A

ABB · Drives & Controllers · Soft Starters · Switzerland · abb.com
Part Number
PSE250-600-70-1  ·  HS 8537.10
Soft start PSE250-600-70-1 250A

ABB PSE250-600-70-1 — The soft starter PSE250-600-70-1 has a rated maximum operational current of 250 A with an operating voltage span from 208.600 V AC. The rated control voltage is between 100.250 V AC at 50/60 Hz. PSE features a two-phase control with a soft start and stop through a voltage or a torque ramp. It has built-in bypass for easy installation and energy saving. A RUN, TOR, and Event signal is available from a relay output in NO (normally open state). The PSE has functions such as current limit, kickstart, analog output, EOL, underload, and locked rotor protection. To interact with PSE, it has an Illuminated display that uses symbols to become language neutral. As an option, you can add an identical external keypad with a rating of IP66. There are three ways to communicate with PSE. It can be done by hardwire inputs Start/Stop or by Reset of fault. Another popular option is the built-in fieldbus communication Modbus RTU. You can also use an external adaptor and a Fieldbus plug. PSE is a true general pur­bag soft starter. It’s a perfect balance be­tween high starting capacity and cost effi­ciency. Very suitable for small to medium-sized three-phase motors with nominal currents from 18.370 A. Typical applications are, for example, pumps, fans, compressors, and conveyors.

Technical Specifications

Manufacturer part number (MPN)PSE250-600-70-1
EAN / GTIN7320500515037
Sales unitpcs
Rated current250 A
Configuration OnlyNo
Country of OriginSweden
CriticalityNo
Lead Time1 day
NoteNo
Product Availability ClassOnly for warranty purposes. Not available for normal sales
Product Sales StatusActive
Storage Location4014
Product Net Width190 mm
Product Net Height435 mm
Product Net Depth / Length237 mm
Rated Operational Voltage208 ... 600 V AC
Rated Control Supply Voltage (U s )100 ... 250 V AC
Rated Control Circuit Voltage (U c )24 V DC
Rated Frequency (f)50/60 Hz; Main Circuit 50 / 60 Hz
Rated Operational Power - In-Line Connection (Pe)(230 V) 75 kW; (400 V) 132 kW; (500 V) 160 kW
Rated Operational Current - In-Line Connection (Ie)250 A
Service Factor Percentage100 %
Overload ProtectionBuilt-in electronic overload protection
Integrated Electronic OverloadYes
Starting Capacity at Maximum Rated Current Ie4xIe for 10s
Ramp Time0 ... 30 s; 1 ... 30 s
Initial Voltage During Start30 ... 70 %
Step Down Voltage Special RampNo %
Current Limit Function1.5 ... 7xIe
Switch for Inside Delta ConnectionNo
Run Signal RelayYes
By-pass Signal RelayYes
Fault Signal RelayYes
Overload Signal RelayYes
Analog Outputs4…20 mA
Signal Indication Completed Start Ramp (LED)Green
Signal Indication Ready to Start/Standby ON (LED)Green
Signal Indication Running R (LED)Green
Signal Indication Ramping Up/Down (LED)Green
Signal Indication Protection (LED)Yellow
Signal Indication Fault (LED)Red
CommunicationModbus-RTU
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal TypeMain Circuit: Bars
Connecting Capacity Main CircuitHole Diameter 8.5 mm; Rigid 1/2 x 2.5 ... 70 mm²; Width and Thickness 17.5x5 mm
Connecting Capacity Control CircuitRigid 1 x 2.5 mm²; Rigid 2 x 1.5 mm²
Connecting Capacity Supply CircuitRigid 1 x 2.5
Tightening TorqueControl Circuit 0.5 N·m; Main Circuit 28 N·m; Supply Circuit 0.5 N·m
Product Main TypePSE250
FunctionSoft start with torque control; Soft start with voltage ramp; Soft stop with torque control; Soft stop with voltage ramp; Kick start; Sequence start; Current limit; Start reverse (external contactors); Automatic restart; Event log
Protection FunctionElectronic overload protection, EOL; Locked rotor protection; Current underload protection
Horsepower Rating UL/CSA(200 ... 208 V AC) Three Phase 75 Hp; (220 ... 240 V AC) Three Phase 100 Hp; (440 ... 480 V AC) Three Phase 200 Hp; (550 ... 600 V AC) Three Phase 250 Hp
Maximum Operating Voltage UL/CSAMain Circuit 600 V
Tightening Torque UL/CSAControl Circuit 4.4 in·lb; Main Circuit 247.8; Supply Circuit 4.4 in·lb
Ambient Air TemperatureOperation -25 ... +60 °C; Storage -40 ... +70 °C
Environmental Product Declaration - EPD1SFC132476D0201
CQC CertificateCQC2018010304109915
Declaration of Conformity - CCC2020980304001510
Declaration of Conformity - CE2CMT2015-005447
DNV Certificate1SFC132383M0001 | TAE0000342
EU Data Act Compliance Declaration1SFC132495M0201
Object Classification CodeQ
ETIM 7EC000640 - Soft starter
eClassV11.0 : 27370907
UNSPSC39121521
IDEA Granular Category Code (IGCC)4740 >> Soft starter

Properties

MOQ1

Cross-References

Attached Documents