| Manufacturer part number (MPN) | AF116-30-11-12 |
| EAN / GTIN | 7320500476369 |
| HS code | 8536.90 |
| Sales unit | pcs |
| Country of Origin | India |
| Product Sales Status | Active |
| Product Net Width | 90 mm |
| Product Net Depth / Length | 126 mm |
| Product Net Height | 150 mm |
| Dimension Diagram | 1SFB535001G1051 |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 3P |
| Rated Operational Voltage | Main Circuit 690 V |
| Rated Frequency (f) | Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (I th ) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 160 A |
| Rated Operational Current AC-1 (I e ) | (690 V) 40 °C 160 A; (690 V) 60 °C 145 A; (690 V) 70 °C 130 A |
| Rated Operational Current AC-3 (I e ) | (415 V) 60 °C 116 A; (440 V) 60 °C 116 A; (500 V) 60 °C 110 A; (690 V) 60 °C 65 A; (380 / 400 V) 60 °C 116 A; (220 / 230 / 240 V) 60 °C 116 A |
| Rated Operational Current AC-3e (I e ) | (415 V) 60 °C 116 A; (440 V) 60 °C 116 A; (500 V) 60 °C 110 A; (690 V) 60 °C 65 A; (380 / 400 V) 60 °C 116 A; (220 / 230 / 240 V) 60 °C 116 A |
| Rated Operational Current DC-1 (I e ) | (110 V) 2 Poles in Series, 40 °C 145 A; (220 V) 3 Poles in Series, 40 °C 145 A |
| Rated Operational Current DC-3 (I e ) | (110 V) 2 Poles in Series, 40 °C 145 A; (220 V) 3 Poles in Series, 40 °C 145 A |
| Rated Operational Current DC-5 (I e ) | (110 V) 2 Poles in Series, 40 °C 145 A; (220 V) 3 Poles in Series, 40 °C 145 A |
| Rated Operational Power AC-3 (P e ) | (415 V) 55 kW; (440 V) 75 kW; (500 V) 75 kW; (690 V) 55 kW; (380 / 400 V) 55 kW; (220 / 230 / 240 V) 30 kW |
| Rated Operational Power AC-3e (P e ) | (415 V) 55 kW; (440 V) 75 kW; (500 V) 75 kW; (690 V) 55 kW; (380 / 400 V) 55 kW; (220 / 230 / 240 V) 30 kW |
| Rated Breaking Capacity AC-3 | 8 x Ie AC-3 |
| Rated Breaking Capacity AC-3e | 8.5 x Ie AC-3e |
| Rated Making Capacity AC-3 | 10 x Ie AC-3 |
| Rated Making Capacity AC-3e | 12 x Ie AC-3e |
| Short-Circuit Protective Devices | gG Type Fuses 250 A |
| Rated Short-time Withstand Current Low Voltage (I cw ) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 928 A; at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 160 A; at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 379 A; at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1160 A; at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 536 A |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 2000 A; cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1000 A |
| Rated Insulation Voltage (U i ) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V; acc. to UL/CSA 600 V |
| Rated Impulse Withstand Voltage (U imp ) | Main Circuit 8 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour; (AC-2 / AC-4) 150 cycles per hour; (AC-3) 300 cycles per hour |
| Mechanical Durability | 5 million |
| Maximum Mechanical Switching Frequency | 300 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
| Rated Control Circuit Voltage (U c ) | 50 Hz 48 ... 130 V; 60 Hz 48 ... 130 V; DC Operation 48 ... 130 V |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 15.1 V·A; Holding at Max. Rated Control Circuit Voltage 60 Hz 15.1 V·A; Holding at Max. Rated Control Circuit Voltage DC 2.4 V·A; Holding at Max. Rated Control Circuit Voltage DC 2.4 W; Pull-in at Max. Rated Control Circuit Voltage 50 Hz 320 V·A; Pull-in at Max. Rated Control Circuit Voltage 60 Hz 320 V·A; Pull-in at Max. Rated Control Circuit Voltage DC 435 V·A; Pull-in at Max. Rated Control Circuit Voltage DC 435 W |
| Power Loss | at Rated Operating Conditions per Pole 6 W |
| Operate Time | Between Coil De-energization and NO Contact Opening 37 ... 47 ms; Between Coil Energization and NO Contact Closing 25 ... 55 ms |
| Connecting Capacity Main Circuit | Flexible 2 x 10 ... 70 mm²; Rigid Cu-Cable 2 x 10 ... 95 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 2x 0.75 ... 2.5 mm²; Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²; Flexible 2x0.75 ... 2.5 mm²; Solid 2 x 1 ... 4 mm²; Stranded 2 x 1 .... 4 mm² |
| Connecting Capacity | Flexible 2 x 10 ... 70 mm²; Rigid Cu-Cable 2 x 10 ... 95 mm² |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20; acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 |
| Tightening Torque | Cable Lug 9 N·m; Main Circuit 8 N·m |
| Terminal Type | Double Clamp |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V |
| General Use Rating UL/CSA | (600 V AC) 160 A |
| Horsepower Rating UL/CSA | (200 V AC) Three Phase 30 hp; (208 V AC) Three Phase 30 hp; (220 ... 240 V AC) Three Phase 40 hp; (440 ... 480 V AC) Three Phase 75 hp; (550 ... 600 V AC) Three Phase 100 hp |
| Full Load Amps Motor Use | (440 ... 480 V AC) Three Phase 96 A; (550 ... 600 V AC) Three Phase 99 A |
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C; Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C; Close to Contactor for Storage -40 ... 70 °C |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility; UL 2799 Zero Waste To Landfill Validation available |
| EcoSolutions Profile | 1SFC100125C0366 |
| End Of Life Disassembling Instructions | 1SFC100112M0001 |
| Environmental Product Declaration - EPD | 1SFC100092D0201; 2TFP200059A1001 |
| Improved Energy Efficiency for Customers | Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line; Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 87.8 % |
| A2L Certificate – UL | 9AKK108468A6693 |
| ABS Certificate | 14-LD1092198-PDA; 14-LD1092198-1-PDA-DUP |
| BV Certificate | BV_36353_A0BV |
| CB Certificate | SEMKO_SE-70479M1 |
| CCS Certificate | GB14T00030 |
| CQC Certificate | CQC2013010304604055 |
| cULus Certificate | 20120925-E36588 |
| Declaration of Conformity - CE | 2CMT2015-005439 |
| Declaration of Conformity - UKCA | 2CMT2020-006118 |
| DNV Certificate | DNV_E-14043 |
| LR Certificate | 16-20064 |
| PRS Certificate | TE_2092_880423_16 |
| RINA Certificate | ELE060313XG_002 |
| UL Listing Card | UL_E36588 |
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4758 >> Iec Contactors |
| E-Number (Finland) | 3706164 |
| E-Number (Norway) | 4117613 |
| E-Number (Sweden) | 3210067 |