Main fuse Circuit Breaker S753DR-E100 SEL (2CDH783010R0822)

ABB · Electrical Components · Fuses · Switzerland · abb.com
Part Number
2CDH783010R0822  ·  HS 8536.90
Main fuse Circuit Breaker S753DR-E100 SEL (2CDH783010R0822)

ABB 2CDH783010R0822 — Selective main circuit-breakers of the S 750 DR series are SMCBs based on DIN VDE 0641-21 with voltage-independent operating principle. This means that they do not rely on a control circuit to make or break contact (SHU) and are therefore particularly suitable for use in energy distribution systems with maximum availability requirements. They offer total selectivity to downstream MCBs and outstanding selectivity to upstream protective devices due to unique current limiting selectivity.

Technical Specifications

Manufacturer part number (MPN)2CDH783010R0822
EAN / GTIN4016779879651
HS code8536.90
Sales unitpcs
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 45.9 %
ABB Site Meeting Group Waste To Landfill TargetNo non-hazardous waste is sent to a landfill
Extended Product LifetimeProduct Durability
End Of Life Disassembling Instructions9AKK108469A4877
Environmental Product Declaration - EPD9AKK108468A5768
Suitable for IsolationYes
Dielectric Test Voltage50 / 60 Hz - 1 min 2 kV
Rated Ultimate Short-Circuit Breaking Capacity (I cu )(400 V AC) 25 kA
Rated Service Short-Circuit Breaking Capacity (I cs )(400 V AC) 12.5 kA
Power Supply ConnectionArbitrary
Contact Position IndicationRed ON / Green OFF
Number of Poles3P
Tightening Torque2.5 ... 3 N·m
Screw Terminal TypeCable Clamp
Actuator MarkingI / O
Recommended Screw DriverCross Recess Pozidriv 2; Slotted 1 x 5.5
Accessories AvailableYes
Connecting CapacityFlexible with Ferrule 2.5 ... 50 mm²; Flexible 2.5 ... 50 mm²; Rigid 2.5 ... 50 mm²; Stranded 2.5 ... 50 mm²
Installation Sizeacc. to DIN 43880 3
Terminal TypeScrew Terminals
Tripping CharacteristicE (Selective)
Rated Operational Voltage400 V AC; acc. to IEC 60947-2 400 V AC
Rated Insulation Voltage (U i )acc. to IEC/EN 60664-1 690 V
Rated Impulse Withstand Voltage (U imp )6 kV; at 2000 m 8 kV; at Sea Level 9.8 kV
Input Voltage TypeAC
Rated Current (I n )100 A
Rated Short-Circuit Capacity(400 V AC) 25 kA
Rated Frequency (f)50 / 60 Hz
Power Lossat Rated Operating Conditions per Pole 12 W
Overvoltage CategoryIV
I²t Characteristic9AKK108466A4492
Ambient Air TemperatureOperation -25 ... +55 °C; Storage -40 ... +70 °C
Degree of ProtectionIP20; Enclosure with Cover IP40
Pollution Degree3
Environmental Conditions28 cycles; with 55 °C / 90-96 %; and 25 °C / 95-100 %
Resistance to Vibrations20 Cycles with Load 0.8 In: 2g 5 ... 150 ... 5 Hz
Resistance to Shock acc. to IEC 60068-2-2730g 3 shocks 11 ms
Product Net Width89 mm
Product Net Height130 mm
Product Net Depth / Length96 mm
Dimension Diagram9AKK108466A4497
Declaration of Conformity - CE2CDK400633D2701
Instructions and Manuals2CDS707001P0004
Mounting TypeDIN-Rail
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715; TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting Positionany
ETIM 9EC001047 - Selective main line circuit breaker
UNSPSC39121614
eClassV11.0 : 27141903
Object Classification CodeF
StandardsIEC/EN 60947-2
Certification AgencyEN; IEC