OVR T2 3N 40-440 P TS QS (2CTB803973R1500)

ABB · Switchgear & Protection · Surge Protectors · Switzerland · abb.com
Part Number
2CTB803973R1500  ·  HS 8535.40
OVR T2 3N 40-440 P TS QS (2CTB803973R1500)

ABB 2CTB803973R1500 — Surge protective devices SPD type 2 protect low-voltage consumer systems against surge voltages as they are tested as SPD type 2 according to IEC 61643-11. The devices are compatible with the System pro M compact series. The SPD with TS are optionally equipped with a auxiliary contact.

Technical Specifications

Manufacturer part number (MPN)2CTB803973R1500 EAN / GTIN: 3660308520005 Sales unit: pcs Country of Origin: India Product Sales Status: Active Carbon Footprint (Full Lifecycle): 17.101466 kg CO₂ eq EcoSolutions Profile: 9AKK108472A3406 Environmental Product Declaration - EPD: 9AKK108472A1711 Type of Low Voltage Distribution System: TT; TN-S Suitable For: To protect the systems against the transient overvoltage (lightning) Nominal AC Voltage of the System (U o ): 400 / 690 V Maximum Continuous Operating Voltage (U c ): (L-PE) 440 V Temporary Overvoltage Test Value (U T ): (L-N) 581 V; (N-PE) 1200 V Rated Service Short-Circuit Breaking Capacity (I cs ): 100 kA Discharge Current: Nominal (8 / 20 µs) 20 kA; I (max, 8 / 20 µs) 40 kA Impulse Current: I (imp, 10 / 350 µs, L-N) 2 kA Short Circuit Withstand Icc: 100 kA Arrester Class: II Number of Protected Poles: 4 Number of Auxiliary Contacts NC: 1 Number of Auxiliary Contacts NO: 1 Number of Poles: 4P Number of Conductors: 4 Position of Neutral Terminals: Right Transmission Standard: Optic Version: Plug-in Product Type: QS Options Provided: Residential, commercial building
Auxiliary Circuit Loadminimum 12Vdc - 10mA; Maximum 250Vac - 1A Preventive Maintenance Feature: No Status Indicator: Yes Fuse Size: 4 modular spacing Cross-Section ( A cross ): Maximum Conductor Solid-Stranded 25 mm²; Maximum Conductor Flexible 16 mm² Rated Voltage (U r ): 400 V AC Voltage Protection Level ( Up): 2.1 kV; (L-N) 1.8 kV; (N-PE) 1.4 kV Power Loss: Total 156 mW Degree of Protection: IP20 Maximum Operating Altitude Permissible: Without Derating 5000 Width in Number of Modular Spacings: 4 Product Net Width: 71.2 mm Product Net Height: 95 mm Product Net Depth / Length: 58 mm CB Certificate: 2CTC432057G1701 CQC Certificate: 9AKK107680A1974 Declaration: 2CTC432056G1701 Declaration of Conformity - CE: 9AKK108466A4410 Instructions and Manuals: 2CTC432096M1701 Mounting Type: DIN-Rail ETIM 9: EC000941 - Surge protection device for power supply systems UNSPSC: 39121610 eClass: V11.0 : 27130805 Object Classification Code: 141DEC Standards: IEC 61643-11 / EN 61643-11 System configuration: TT System configuration DC: No System configuration IT: No System configuration TN: Yes System configuration TN-C: No System configuration TT: Yes System configuration other: No Nominal discharge surge current (8/20): 20 kA Max. discharge surge current (8/20): 20 kA Short-circuit-proof: No Nominal voltage AC: 400 V Max. continuous voltage AC: 440 V Max. continuous voltage DC: 560 V Voltage protection level L-N: 1.8 kV Voltage protection level N-PE: 1.4 kV Max. overcurrent protection device, series connection (fuse): 125 A Short-circuit breaking capacity (Isccr): 100 kA Integrated short-circuit protection: No Integrated short-circuit protection selective to fuse gG: 125 A Integrated backup fuse: No Leakage-current free: Yes Construction size: 4 modular spacing Max. conductor cross section solid (solid, stranded): 25 mm² Max. conductor cross section flexible (fine-strand): 16 mm² With remote signalling contact: Yes Signalling at the device: Optical Category type 2: Yes

Properties

MOQ1

Cross-References