cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

ABB 2CTB803872R5200 OVR T2 2L 40-440 P TS QS Surge Protective Device

ABB · Switchgear & Protection · Surge Protectors · Switzerland · abb.com
Part Number
2CTB803872R5200  ·  HS 8535.40
ABB 2CTB803872R5200 OVR T2 2L 40-440 P TS QS Surge Protective Device

ABB 2CTB803872R5200 — OVR T2 2L 40-440 P TS QS Surge Protective Device.

Technical Specifications

Manufacturer part number (MPN)2CTB803872R5200 EAN / GTIN: 3660308520630 Sales unit: pcs Environmental Product Declaration - EPD: 9AKK108472A1711 Type of Low Voltage Distribution System: TN-S; IT Suitable For: To protect the systems against the transient overvoltage (lightning) Nominal AC Voltage of the System (U o ): 400 / 690 V Maximum Continuous Operating Voltage (U c ): (L-PE) 440 V Temporary Overvoltage Test Value (U T ): 581 V Rated Service Short-Circuit Breaking Capacity (I cs ): 100 kA Discharge Current: Nominal (8 / 20 µs) 20 kA; I (max, 8 / 20 µs) 40 kA Impulse Current: I (imp, 10 / 350 µs, L-N) 2 kA Short Circuit Withstand Icc: 100 kA Arrester Class: II Number of Protected Poles: 2 Number of Auxiliary Contacts NC: 1 Number of Auxiliary Contacts NO: 1 Number of Poles: 2P Number of Conductors: 2 Transmission Standard: Optic Version: Plug-in Product Type: QS Options Provided: Residential, commercial building
Auxiliary Circuit Loadminimum 12Vdc - 10mA; Maximum 250Vac - 1A Preventive Maintenance Feature: No Status Indicator: Yes Fuse Size: 2 modular spacing Cross-Section ( A cross ): Maximum Conductor Solid-Stranded 35 mm²; Maximum Conductor Flexible 25 mm² Rated Voltage (U r ): 400 V AC Voltage Protection Level ( Up): 1.8 kV; (L-N) 1.8 kV; (N-PE) 1.8 kV Degree of Protection: IP20 Maximum Operating Altitude Permissible: Without Derating 5000 Width in Number of Modular Spacings: 2 Product Net Width: 35.6 mm Product Net Height: 95 mm Product Net Depth / Length: 58 mm CB Certificate: 2CTC432057G1701 CQC Certificate: 9AKK107680A1974 Declaration: 2CTC432056G1701 Declaration of Conformity - CE: 9AKK108466A4410 Instructions and Manuals: 2CTC432105M1701 Mounting Type: DIN-Rail ETIM 9: EC000941 - Surge protection device for power supply systems eClass: V11.0 : 27130805 Object Classification Code: 141DEC Standards: IEC 61643-11 / EN 61643-11 System configuration DC: No System configuration IT: No System configuration TN: Yes System configuration TN-C: Yes System configuration TT: No System configuration other: No Nominal discharge surge current (8/20): 20 kA Max. discharge surge current (8/20): 20 kA Short-circuit-proof: Yes Nominal voltage AC: 400 V Max. continuous voltage AC: 440 V Max. continuous voltage DC: 560 V Voltage protection level L-N: 1.8 kV Voltage protection level N-PE: 1.8 kV Max. overcurrent protection device, series connection (fuse): 125 A Short-circuit breaking capacity (Isccr): 100 kA Integrated short-circuit protection: No Integrated short-circuit protection selective to fuse gG: 125 A Integrated backup fuse: No Leakage-current free: No Construction size: 2 modular spacing Max. conductor cross section solid (solid, stranded): 35 mm² Max. conductor cross section flexible (fine-strand): 25 mm² With remote signalling contact: Yes Signalling at the device: Optical Category type 2: Yes Country of origin: Bulgaria

Properties

MOQ1

Cross-References

Attached Documents