cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

ABB DDA802 RCD Block — 2-Pole, Type A, 100 A, 1 A, Selective, for S800 MCB (2CSB802201R5000)

ABB · Electrical Components · RCDs & RCBOs · Switzerland · abb.com
Part Number
2CSB802201R5000  ·  HS 8536.30
ABB DDA802 RCD Block — 2-Pole, Type A, 100 A, 1 A, Selective, for S800 MCB (2CSB802201R5000)

The ABB 2CSB802201R5000 is a DDA802 residual current device (RCD) block from the DDA800 range. It assembles on site onto an ABB S800 series miniature circuit breaker and adds residual-current protection to that breaker's overcurrent protection. Building a board this way means the earth-fault function can be added only to the ways that need it, instead of holding a separate RCBO in every rating. It is 2-pole, rated 100 A, with a rated residual current of 1 A. Type A means it responds to sinusoidal AC residual currents and to pulsating DC residual currents, which is what circuits feeding electronic loads require. At 1 A it is intended for protection against earth-fault fire and for equipment protection, not for protection against direct contact — that requires a 30 mA device. This is the selective (S-type) version. It trips with a deliberate time delay so that an instantaneous RCD downstream clears the fault first and only the affected circuit is lost — the reason a selective device belongs at the head of a board rather than on a final circuit. Rated voltage 230 V AC; 240 V AC; 400 V AC. It fits S800S, S800N, S800C and S800B miniature circuit breakers. Supplied by cBallast on quote-to-invoice terms; lead time and freight are quoted per RFQ against the destination Incoterm.

Technical Specifications

Manufacturer part number (MPN)2CSB802201R5000
EAN / GTIN8012542547433
Sales unitpcs
Type of Residual CurrentType A
Suitable ForS800S; S800N; S800C; S800B
Maximum Surge Current5 kA
Leakage Current TypeA
Number of Poles2P
Operating CharacteristicSelective
Connecting CapacityRigid 6 ... 50 mm²; Flexible 6 ... 70 mm²
Short-Circuit Current Rating (SCCR)1 ... 1 A
Rated Voltage (U r )230 V AC; 240 V AC; 400 V AC
Rated Operational Voltage400/690 V
Rated Insulation Voltage (U i )acc. to IEC/EN 60664-1 690 V
Rated Impulse Withstand Voltage (U imp )6 kV
Rated Current (I n )100 A
Rated Residual Current1000 mA
Rated Frequency (f)50 / 60 Hz
Power LossTotal 7 W
Ambient Temperature-25...60 °C
Ambient Air TemperatureOperation -25 ... 60 °C
Degree of ProtectionIP2X
Pollution Degree2
Environmental Informationrefer to RoHS information
Width in Number of Modular Spacings4.5
Product Net Width81 mm
Product Net Height108.2 mm
Product Net Depth / Length82.3 mm
Declaration of Conformity - CE9AKK106713A5616
Instructions and Manuals2CSB427001D0003
ETIM 9EC002297 - Residual current circuit breaker (RCCB) module
UNSPSC39121601
eClassV11.0 : 27142210
Object Classification CodeF
StandardsIEC EN 60947-2 Ann. B
Nominal voltage230–400 V
Nominal current100 A
Rated fault current adjustableNo
Rated fault current1 A
Delay adjustableNo
Surge current capacity5 kA
Frequency50/60 Hz
Rated insulation voltage Ui690 V
Rated impulse withstand voltage Uimp6 kV
Connectable conductor cross section solid-core6–50 mm²
Connectable conductor cross section multi-wired6–70 mm²
Anti-nuisance tripping versionYes
With interlocking deviceNo
Ambient temperature during operating-25–60 °C
Country of originItaly
Product familyABB DDA800 RCD block (System pro M compact)
Device typeAdd-on residual current device (RCD) block for MCB
ModelDDA802
Tripping characteristicSelective / time-delayed (S)
Protection purposeProtection against earth-fault fire / equipment protection

Properties

MOQ1

Cross-References

Attached Documents