ABB DDA802 RCD Block — 2-Pole, Type A, 63 A, 300 mA, Selective, for S800 MCB (2CSB802201R3630)

ABB · Electrical Components · RCDs & RCBOs · Switzerland · abb.com
Part Number
2CSB802201R3630  ·  HS 8536.30
ABB DDA802 RCD Block — 2-Pole, Type A, 63 A, 300 mA, Selective, for S800 MCB (2CSB802201R3630)

The ABB 2CSB802201R3630 is a DDA802 residual current device (RCD) block from the DDA800 range. It assembles on site onto an ABB S800 series miniature circuit breaker and adds residual-current protection to that breaker's overcurrent protection. Building a board this way means the earth-fault function can be added only to the ways that need it, instead of holding a separate RCBO in every rating. It is 2-pole, rated 63 A, with a rated residual current of 300 mA. Type A means it responds to sinusoidal AC residual currents and to pulsating DC residual currents, which is what circuits feeding electronic loads require. At 300 mA it is intended for protection against earth-fault fire and for equipment protection, not for protection against direct contact — that requires a 30 mA device. This is the selective (S-type) version. It trips with a deliberate time delay so that an instantaneous RCD downstream clears the fault first and only the affected circuit is lost — the reason a selective device belongs at the head of a board rather than on a final circuit. Rated voltage 230 V AC; 240 V AC; 400 V AC. It fits S800P, S800S, S800N, S800C and S800B miniature circuit breakers. Supplied by cBallast on quote-to-invoice terms; lead time and freight are quoted per RFQ against the destination Incoterm.

Technical Specifications

Manufacturer part number (MPN)2CSB802201R3630
EAN / GTIN8012542920601
Sales unitpcs
Type of Residual CurrentType A
Suitable ForS800P; S800S; S800N; S800C; S800B
Maximum Surge Current5 kA
Leakage Current TypeA
Number of Poles2P
Operating CharacteristicSelective
Connecting CapacityRigid 6 ... 50 mm²; Flexible 6 ... 70 mm²
Short-Circuit Current Rating (SCCR)0.3 ... 0.3 A
Rated Voltage (U r )230 V AC; 240 V AC; 400 V AC
Rated Operational Voltage400/690 V
Rated Insulation Voltage (U i )acc. to IEC/EN 60664-1 690 V
Rated Impulse Withstand Voltage (U imp )6 kV
Rated Current (I n )63 A
Rated Residual Current300 mA
Rated Frequency (f)50 / 60 Hz
Power LossTotal 9 W
Ambient Temperature-25...60 °C
Ambient Air TemperatureOperation -25 ... 60 °C
Degree of ProtectionIP2X
Pollution Degree2
Environmental Informationdocument not needed
Width in Number of Modular Spacings4.5
Product Net Width81 mm
Product Net Height108.2 mm
Product Net Depth / Length82.3 mm
Declaration of Conformity - CE9AKK106713A5616
Instructions and Manuals2CSB427001D0003
ETIM 9EC002297 - Residual current circuit breaker (RCCB) module
UNSPSC39121601
eClassV11.0 : 27142210
Object Classification CodeF
StandardsIEC EN 60947-2 Ann. B
Nominal voltage230–400 V
Nominal current63 A
Rated fault current adjustableNo
Rated fault current0.3 A
Delay adjustableNo
Surge current capacity5 kA
Frequency50/60 Hz
Rated insulation voltage Ui690 V
Rated impulse withstand voltage Uimp6 kV
Connectable conductor cross section solid-core6–50 mm²
Connectable conductor cross section multi-wired6–70 mm²
Anti-nuisance tripping versionYes
With interlocking deviceNo
Ambient temperature during operating-25–60 °C
Country of originItaly
Product familyABB DDA800 RCD block (System pro M compact)
Device typeAdd-on residual current device (RCD) block for MCB
ModelDDA802
Tripping characteristicSelective / time-delayed (S)
Protection purposeProtection against earth-fault fire / equipment protection