ABB DDA802 RCD Block — 2-Pole, Type A APR, 100 A, 30 mA, 10 ms Delay, for S800 MCB (2CSB802401R1000)

ABB · Electrical Components · RCDs & RCBOs · Switzerland · abb.com
Part Number
2CSB802401R1000  ·  HS 8536.30
ABB DDA802 RCD Block — 2-Pole, Type A APR, 100 A, 30 mA, 10 ms Delay, for S800 MCB (2CSB802401R1000)

The ABB 2CSB802401R1000 is a DDA802 residual current device (RCD) block from the DDA800 range. It assembles on site onto an ABB S800 series miniature circuit breaker and adds residual-current protection to that breaker's overcurrent protection. Building a board this way means the earth-fault function can be added only to the ways that need it, instead of holding a separate RCBO in every rating. It is 2-pole, rated 100 A, with a rated residual current of 30 mA. Type A means it responds to sinusoidal AC residual currents and to pulsating DC residual currents, which is what circuits feeding electronic loads require. At 30 mA it is rated for protection of people against electric shock, which is the sensitivity required for socket outlets and other circuits where direct contact is foreseeable. This is the APR high-immunity version, which trips with a 10 ms delay. The delay lets it ride through the brief leakage surges produced by switching, by long cable runs and by the input filters of electronic equipment, instead of nuisance-tripping on them. Rated voltage 230 V AC; 240 V AC; 400 V AC. It fits S800S, S800N, S800C and S800B miniature circuit breakers. Supplied by cBallast on quote-to-invoice terms; lead time and freight are quoted per RFQ against the destination Incoterm.

Technical Specifications

Manufacturer part number (MPN)2CSB802401R1000
EAN / GTIN8012542544630
Sales unitpcs
Rated current100 A
Type of Residual CurrentType A APR
Suitable ForS800S; S800N; S800C; S800B
Maximum Surge Current3 kA
Leakage Current TypeA
Number of Poles2P
Operating Characteristic10ms Delay (High Immunity)
Connecting CapacityRigid 6 ... 50 mm²; Flexible 6 ... 70 mm²
Short-Circuit Current Rating (SCCR)0.03 ... 0.03 A
Rated Voltage (U r )230 V AC; 240 V AC; 400 V AC
Rated Operational Voltage400/690 V
Rated Insulation Voltage (U i )acc. to IEC/EN 60664-1 690 V
Rated Impulse Withstand Voltage (U imp )6 kV
Rated Current (I n )100 A
Rated Residual Current30 mA
Rated Frequency (f)50 / 60 Hz
Power LossTotal 7 W
Ambient Temperature-25...60 °C
Ambient Air TemperatureOperation -25 ... 60 °C
Degree of ProtectionIP2X
Pollution Degree2
Environmental Informationrefer to RoHS information
Width in Number of Modular Spacings4.5
Product Net Width81 mm
Product Net Height108.2 mm
Product Net Depth / Length82.3 mm
Declaration of Conformity - CE9AKK106713A5616
Instructions and Manuals2CSB427001D0003
ETIM 9EC002297 - Residual current circuit breaker (RCCB) module
UNSPSC39121601
eClassV11.0 : 27142210
Object Classification CodeF
StandardsIEC EN 60947-2 Ann. B
Nominal voltage230–400 V
Nominal current100 A
Rated fault current adjustableNo
Rated fault current0.03 A
Delay adjustableNo
Surge current capacity3 kA
Frequency50/60 Hz
Rated insulation voltage Ui690 V
Rated impulse withstand voltage Uimp6 kV
Connectable conductor cross section solid-core6–50 mm²
Connectable conductor cross section multi-wired6–70 mm²
Anti-nuisance tripping versionYes
With interlocking deviceNo
Ambient temperature during operating-25–60 °C
Country of originItaly
Product familyABB DDA800 RCD block (System pro M compact)
Device typeAdd-on residual current device (RCD) block for MCB
ModelDDA802
Tripping characteristicAPR — high immunity, 10 ms delay
Protection purposeProtection of people against electric shock

Properties

MOQ1

Cross-References

Attached Documents