OVR T2 3N 80-275S P QS (2CTB815708R2000)

ABB · Switchgear & Protection · Surge Protectors · Switzerland · abb.com
Part Number
2CTB815708R2000  ·  HS 8536.30
OVR T2 3N 80-275S P QS (2CTB815708R2000)

ABB 2CTB815708R2000 — Surge protective devices SPD type 2 protect low-voltage consumer systems against surge voltages as they are tested as SPD type 2 according to IEC 61643-11. The devices are compatible with the System pro M compact series. The SPD with TS are optionally equipped with a auxiliary contact. The variants with reserve varistor (s) offer additional protection for the system, as the SPD is not completely disconnected from the mains at the end of its service life, but with an additional smaller varistor still guarantees basic protection and the system thus until the surge arrester is replaced is still protected.

Technical Specifications

Manufacturer part number (MPN)2CTB815708R2000
EAN / GTIN3660308525505
Sales unitpcs
Country of OriginChina
Lead Time28 day
Product Sales StatusInactive
Carbon Footprint (Full Lifecycle)31.686122 kg CO₂ eq
EcoSolutions Profile9AKK108472A3406
Environmental Product Declaration - EPD9AKK108472A1711
Type of Low Voltage Distribution SystemTT; TN-S
Suitable ForTo protect the systems against the transient overvoltage (lightning)
Nominal AC Voltage of the System (U o )230 / 400 V
Maximum Continuous Operating Voltage (U c )(L-PE) 275 V
Temporary Overvoltage Test Value (U T )(L-N) 337 V; (N-PE) 1200 V
Rated Service Short-Circuit Breaking Capacity (I cs )100 kA
Discharge CurrentNominal (8 / 20 µs) 20 kA; I (max, 8 / 20 µs) 80 kA
Impulse CurrentI (imp, 10 / 350 µs, L-N) 6.25 kA
Short Circuit Withstand Icc100 kA
Arrester ClassII
Number of Protected Poles4
Number of Poles4P
Number of Conductors4
Position of Neutral TerminalsRight
Transmission StandardOptic
VersionPlug-in
Product TypeQS
Options ProvidedIndustry, commercial building
Preventive Maintenance FeatureYes
Status IndicatorYes
Fuse Size4 modular spacing
Cross-Section ( A cross )Maximum Conductor Solid-Stranded 35 mm²; Maximum Conductor Flexible 25 mm²
Rated Voltage (U r )230 V AC
Voltage Protection Level ( Up)1.4 kV; (L-N) 1.4 kV; (N-PE) 1.4 kV
Power LossTotal 49 mW
Degree of ProtectionIP20
Maximum Operating Altitude PermissibleWithout Derating 5000
Width in Number of Modular Spacings4
Product Net Width71.2 mm
Product Net Height88 mm
Product Net Depth / Length76.7 mm
CQC Certificate9AKK107680A1974
Declaration2CTC432056G1701
Declaration of Conformity - CE9AKK108466A4617
Instructions and Manuals2CTC432106M1701
Mounting TypeDIN-Rail
ETIM 9EC000941 - Surge protection device for power supply systems
UNSPSC39121610
eClassV11.0 : 27130805
Object Classification Code141DCC
StandardsIEC 61643-11 / EN 61643-11
System configuration DCNo
System configuration ITNo
System configuration TNYes
System configuration TN-CNo
System configuration TTYes
System configuration otherNo
Nominal discharge surge current (8/20)20 kA
Max. discharge surge current (8/20)20 kA
Short-circuit-proofYes
Nominal voltage AC230 V
Max. continuous voltage AC275 V
Max. continuous voltage DC350 V
Voltage protection level L-N1.4 kV
Voltage protection level N-PE1.4 kV
Max. overcurrent protection device, series connection (fuse)160 A
Short-circuit breaking capacity (Isccr)100 kA
Integrated short-circuit protectionNo
Integrated short-circuit protection selective to fuse gG160 A
Integrated backup fuseNo
Leakage-current freeYes
Construction size4 modular spacing
Max. conductor cross section solid (solid, stranded)35 mm²
Max. conductor cross section flexible (fine-strand)25 mm²
With remote signalling contactYes
Signalling at the deviceOptical
Category type 2Yes